DTC B110913 indicates an open signal circuit for the PM2 — Qin Plus
DTC B110913 indicates an open signal circuit for the PM2.5 rapid detector (in-cabin air quality sensor).
This sensor typically mounts inside the air conditioning system intake duct.
It monitors in-cabin PM2.5 concentration in real time and provides data to the automatic air conditioning system for intelligent control of the air purification function.
The BYD diagnostic protocol uses sub-code '13' to specifically indicate an open signal circuit.
Although this fault theoretically affects a comfort feature, BYD Qin series vehicles classify it as a Level 3 (severe) fault.
This classification occurs because the air conditioning system interacts with the battery thermal management system (e.g., monitoring battery cooling intake air quality).
The fault can disable the automatic air conditioning mode and prevent the air purification function from operating.
In extreme cases, it affects the battery compartment intake air quality assessment, triggering the 'repair immediately' strategy.
- 1Internal open circuit or aging failure of the PM2.5 sensor, interrupting signal output.
- 2Loose sensor wiring harness connector, backed-out pin, or corroded/oxidized terminal causing poor contact.
- 3Vibration wear or crushing at the firewall grommet or instrument panel frame broke the harness wire.
- 4Blown fuse in the sensor 5V reference voltage circuit or ground circuit (e.g., F2-17 air conditioning system fuse)
- 5Air conditioning controller (AC ECU) internal signal sampling circuit fault; unable to recognize sensor input.
- 1Use VDS2000 or the BYD dedicated diagnostic tool to read the complete fault codes and freeze frame data. Confirm the ambient temperature, vehicle speed, and air conditioning status at the time of the fault. After ruling out an intermittent fault, clear the fault codes and perform a road test to verify if the fault returns.
- 2Remove the front passenger glove box or air conditioning filter. Visually inspect the PM2.5 sensor (usually marked 'Air Quality Sensor') installation. Verify the wiring harness connector is fully seated. Check the terminals for green oxidation or backed-out pins. Clean with electrical contact cleaner if necessary.
- 3Disconnect the sensor connector. Use a multimeter to measure the supply voltage and ground resistance on the wiring harness side. The supply voltage must be 5 V ± 0.25 V, and the ground resistance must be less than 1 Ω. If the supply voltage is abnormal, check fuse F2-17 and the supply circuit. If the ground resistance is abnormal, check ground point G301.
- 4Measure the continuity of the signal wire (usually yellow or blue) between the sensor connector and pin T32-15 of the air conditioning controller connector. Normal resistance should be less than 2Ω. If resistance is infinite, check the wiring harness section by section. Inspect the firewall wiring grommet and dashboard frame retaining clips for wear.
- 5If the wiring harness is normal, use an oscilloscope to check the sensor signal output (expect a PWM signal or analog voltage), or install a known-good PM2.5 sensor for testing. If the fault code clears, the sensor is faulty.
- 6If the fault persists after replacing the sensor, check the A/C controller software version and upgrade to the latest version if necessary. If the software is correct, measure the controller internal sampling resistor to confirm an internal circuit fault and replace the AC ECU.
Qin Pro EV sensor connector worked loose, causing intermittent fault codes
Qin EV300 wiring harness chafing caused signal wire open circuit
Qin Pro DM sensor body aging failure
Qin EV300 wiring harness chafing caused signal wire open circuit