This DTC indicates the Battery Thermal Management Electric Water Pump supply voltage falls below the system normal operating threshold (typically below 9V or 10 — Seal 6 EV
This DTC indicates the Battery Thermal Management Electric Water Pump supply voltage falls below the system normal operating threshold (typically below 9V or 10.5V, depending on vehicle calibration).
In the BYD Qin EV thermal management system, this water pump circulates coolant between the battery pack and the heat exchanger to maintain cell temperature within the optimal 15–35°C operating range.
During an undervoltage fault, the pump may experience an abnormal speed drop, stop intermittently, or fail completely, reducing battery cooling and heating efficiency.
Prolonged operation with this fault can trigger the BMS power limit protection strategy (reduced-power driving) and, in extreme cases, pose a risk of battery thermal runaway.
The air conditioning controller (or thermal management controller) triggers this fault upon detecting an abnormal PWM feedback signal from the water pump or an abnormal power supply voltage.
- 1Low-voltage battery (12V auxiliary battery) aging or under-voltage: Voltage drops below 9V during vehicle startup, causing unstable power supply to the water pump.
- 2Poor contact in the water pump power supply circuit or damaged wiring harness: Connector oxidation or terminal back-out due to high front compartment temperatures, or vehicle wiring harness wear, increases contact resistance and causes a voltage drop.
- 3Water pump internal motor short circuit or seizure: Worn water pump bearings or a seized impeller abnormally increase operating current, pulling down the supply voltage.
- 4Fuse or relay fault: Water pump power supply circuit fuse (usually 15A-20A) blown internally, poor connection at the fuse holder, or burnt relay contacts causing a voltage drop.
- 5Thermal management controller output abnormal: A damaged water pump PWM drive module or power output stage MOSFET cannot provide stable voltage.
- 1Fault confirmation and Freeze Frame reading: Use the VDS2000/VDS6000 diagnostic tool to read the fault code, confirm if it is a current fault (Current), and record the ambient temperature, battery temperature, and water pump duty cycle data at the time of the fault.
- 2Low-voltage battery check: Measure the 12V battery static voltage (≥12.4V) and starting voltage (≥9.6V). Check the battery state of health (SOH). Charge or replace the battery if necessary.
- 3Power supply circuit measurement: Disconnect the negative terminal. Locate the battery thermal pipe water pump connector (usually on the right side of the front compartment or at the front of the battery pack). Measure the voltage between connector Pin 1 (constant power) and Pin 2 (ground). With the ignition ON, the voltage must be ≥11.5 V. If the voltage is below 10 V, check fuse F1/16 or F2/13 (depending on vehicle configuration) and relay E13 in the front compartment fuse box.
- 4Wiring harness continuity check: Measure the wiring harness resistance between the water pump connector and the thermal management controller (or air conditioning controller). Resistance must be <1Ω. Inspect the connector for backed-out pins, oxidation, or water corrosion. Focus on areas where the front compartment wiring harness rubs against the vehicle body.
- 5Water pump load test: Use an oscilloscope to measure the voltage waveform during water pump operation. If the voltage drop exceeds 2V, directly connect an external 12V regulated power supply to test the water pump. If the water pump makes abnormal noise or the current is >8A (normal 2-4A), replace the water pump assembly.
- 6Controller diagnosis: If the wiring and water pump are normal, check the thermal management controller software version. Upgrade to the latest version if necessary. Measure the voltage at the controller output terminal. If the output is abnormal, replace the controller.
- 7Repair verification: Clear the fault code, start the air conditioning in cooling/heating mode, and monitor the data stream to confirm 'Battery Coolant Pump Speed' reaches the target speed (usually 2000-4000rpm). Perform a 30-minute road test to confirm the fault does not recur.
Oxidised water pump connector causing intermittent undervoltage on Qin EV
Aging 12V battery caused cascading undervoltage failure in water pump
Internal short circuit in the water pump burned the fuse holder.
Wiring harness wear caused high-resistance connection and voltage drop