B1677-00

DTC B1677-00 on BYD new energy vehicles (including DM hybrid and EV models) is a manufacturer-defined fault code — Seal 6 EV

Safety System

DTC B1677-00 on BYD new energy vehicles (including DM hybrid and EV models) is a manufacturer-defined fault code.

It denotes a communication fault between the Battery Management System (BMS) and the Motor Control Unit (MCU/VTOG), or a High Voltage Interlock Loop (HVIL) fault, rather than an SRS airbag crash sensor fault.

This fault indicates an open circuit, short circuit, or communication interruption in the high-voltage safety interlock loop.

When the BMS detects a high-voltage safety risk, it triggers a protection mechanism and cuts off the high-voltage power supply, preventing the vehicle from powering on, driving, or charging.

This fault involves high-voltage safety and requires immediate repair.

The B1677-00 fault code on the Seal 6 EV indicates a high-voltage safety interlock loop (HVIL) fault or communication failure between the Battery Management System and Motor Control Unit. This critical issue cuts high-voltage power, preventing driving or charging. Common causes include loose HVIL plugs or corroded pins. Immediate repair at an authorised dealer is essential. Typical repair cost data is available from 5 recorded cases.
5
Cases Logged
5
Causes
  • 1Loose high-voltage interlock (HVIL) plug, backed-out pins, poor contact, or corroded/oxidized pins causing abnormal circuit resistance.
  • 2Open circuit, short to ground, wiring harness wear, interference, or water ingress in the high-voltage interlock circuit.
  • 3CAN communication wiring harness fault between BMS and MCU (open circuit, short circuit, electromagnetic interference)
  • 4Motor controller (VTOG/MCU) internal CAN communication module or high-voltage interlock detection circuit faulty
  • 5High-voltage power distribution unit (PDU) internal interlock microswitch fault, or Manual Service Disconnect (MSD) not fully seated.
  • 1
    Use the BYD dedicated diagnostic tool (ED400/Launch 431) to read the BMS system fault codes, confirm B1677-00 and related freeze frame data, and check for accompanying communication fault codes.
  • 2
    Perform a high-voltage interlock loop continuity test: disconnect the low-voltage battery negative terminal, wait 5 minutes, and measure the total resistance of the HVIL circuit using a multimeter. Normal resistance is less than 10Ω. If the resistance is excessive or infinite, check the interlock pins of each high-voltage component section by section (BMS → service disconnect switch → power battery → PDU → MCU → compressor → PTC).
  • 3
    Check the CAN communication circuit: Measure the CAN-H (approx. 2.6V) and CAN-L (approx. 2.4V) voltages at the OBD diagnostic port. Check the CAN line continuity and terminal resistance (approx. 60Ω) between the BMS and MCU to rule out open circuits, short circuits, or interference.
  • 4
    Visually inspect all high-voltage interlock connectors (orange connectors) to verify they are fully locked and show no backed-out pins, burn marks, corrosion, or signs of water ingress. Focus on wiring harness wear in high-temperature areas of the motor compartment.
  • 5
    If the wiring is normal but the fault persists, swap or replace the suspected controller (MCU, PDU, etc.) to determine if the internal interlock detection circuit or communication module is faulty.
  • 6
    After repairing or replacing the faulty wiring harness/connector, reconnect the low-voltage battery and clear the fault code. Perform a high-voltage system self-check and power-on test. Confirm the READY light illuminates normally and perform a road test to verify.
BYD DTC AI Analysis

Qin DM motor controller high-voltage interlock terminal pin backed out

✓
2015 Qin DM. Dashboard displayed 'Check Power System', EV mode did not work, and the vehicle could not charge. Diagnosis found the BMS reported DTC B1677-00 (communication fault). Testing revealed the high-voltage interlock pin at the motor controller had backed out and deformed, causing an open circuit. Re-crimped the interlock terminal and secured the wiring harness, clearing the fault and restoring high-voltage system operation.
Original source ↗
BYD DTC AI Analysis

Tang DM PTC water heater interlock connector corrosion

✓
2018 Tang DM suddenly lost power while driving and displayed a powertrain system fault. Read DTC B1677-00 indicating a high-voltage interlock loop fault. Step-by-step inspection traced the fault to internal corrosion and oxidation in the PTC water heater high-voltage interlock connector, causing intermittent circuit resistance. Replacing the PTC high-voltage interlock connector and waterproofing it resolved the issue.
Original source ↗
BYD DTC AI Analysis

e5 motor controller: internal CAN module damaged

✓
2016 e5 electric taxi failed to start, READY light off. BMS reported DTC B1677-00 (BMS-VTOG communication fault). Checked external CAN wiring and power supply – normal. Measured termination resistance – normal. Diagnosed as internal CAN communication module failure in the motor controller. Replaced the VTOG controller and flashed the software. Fault resolved.
Original source ↗
BYD DTC AI Analysis

Worn CAN wiring harness causing interference – BYD Song Pro DM

✓
A 2019 Song Pro DM suffered intermittent EV mode failure, occurring more frequently in high-temperature conditions. Communication monitoring revealed frame loss between the BMS and MCU. Inspection found the engine bay harness chafing against a body bracket, damaging the CAN-H wire insulation and risking a short to ground. The fault did not recur after repairing the damaged harness and adjusting its routing.
Original source ↗
BYD DTC AI Analysis

Han EV high voltage distribution box interlock loose connection

✓
A new 2020 Han EV wouldn't start after charging and reported a high voltage system fault. DTC B1677-00 indicated a high voltage interlock abnormality. Found the high voltage distribution box (PDU) interlock connector not fully locked; a loose internal microswitch clip caused a poor connection. Replaced the high voltage distribution box assembly. Fault resolved.
Original source ↗