DTC B1695-00 indicates the airbag control unit (SRS ECU) detected its operating supply voltage exceeds the system safety threshold (typically >16V) — Seal 6 EV
DTC B1695-00 indicates the airbag control unit (SRS ECU) detected its operating supply voltage exceeds the system safety threshold (typically >16V).
On BYD new energy vehicles, this fault means the 12V low-voltage system supply voltage rose abnormally, exceeding the tolerance range of the SRS ECU internal circuits.
The SRS system is highly sensitive to voltage.
Excessive voltage can cause reference voltage drift in the internal A/D converter, capacitor breakdown, or unintended airbag deployment.
As a safety mechanism, the ECU illuminates the airbag warning lamp, stores the fault code, and enters a fail-safe mode.
This mode disables the airbags and seat belt pretensioners, preventing abnormal voltage from causing unintended deployment or failure during a collision.
- 1DC-DC converter (high voltage to low voltage) fault or regulator failure, causing output voltage to exceed 16V and fail to stabilize within the normal 13.5-14.5V range.
- 212V battery aging, sulfation, or internal short circuit reduces charge acceptance, causing terminal voltage to rise rapidly to an abnormally high level during initial charging.
- 3Intermittent short circuit between the SRS ECU power supply circuit and the high-voltage circuit, or poor contact in the ground circuit (GND), causes reference voltage drift, leading the ECU to detect a false high voltage.
- 4Generator regulator fault (during engine operation on hybrid models), causing excessive charging system output voltage (>15.5V).
- 5Unauthorized vehicle modification with a high-power inverter, in-vehicle power amplifier, or additional charging equipment causes sudden power system load changes, leading to a delayed voltage regulator response that generates instantaneous high-voltage spikes.
- 1Use the VDS2000 or BYD dedicated diagnostic tool to read the DTC freeze frame data. Record the exact voltage, vehicle speed, timestamp, and system load status at the time of the fault to determine whether it is a persistent or intermittent fault.
- 2Measure the current 12V battery static voltage (12.4-12.8V with the vehicle off). Enter Ready mode or start the engine and measure the dynamic charging voltage. Verify if the voltage continuously exceeds 15.5V or exhibits fluctuation spikes.
- 3For new energy vehicles, check the DC-DC converter output voltage; for hybrid/fuel vehicles, check the alternator output voltage and regulator operating status to determine if the voltage regulation component has failed.
- 4Disconnect the battery negative terminal, wait 3 minutes, then remove the SRS ECU. Check the voltage drop and circuit resistance at the ECU B+ (constant power), IG (ignition power), and GND (ground) terminals. Verify the ground circuit resistance is < 1Ω and the power supply wiring shows no damage or burn marks.
- 5Perform a 12V battery health check (internal resistance test, cold cranking amps (CCA) test, charge and discharge curve test). If internal resistance is >10 mΩ or the CCA value is below 60% of the rated value, replace the battery.
- 6Replace the faulty component (DC-DC converter, alternator regulator, battery, or wiring harness) based on the inspection results. After repair, use the diagnostic tool to clear the fault code and perform 3 complete ignition cycles (OFF→ON→START→ON→OFF) for a self-test.
- 7Use the diagnostic tool to perform the SRS system function test and read the circuit resistance of the airbags, side curtain airbags, and seat belt pretensioners (normal: 1.5-3.0 Ω). Confirm no new fault codes before returning the vehicle.
BYD S6 alternator regulator fault causing SRS high voltage
BYD Qin EV300 DC-DC converter output voltage abnormal
BYD E1: Loose SRS ECU power connector causes intermittent high voltage warning
BYD Qin 80 battery sulfation causing excessive charging voltage