This fault code indicates a short to ground or open circuit in the rear HVAC blower motor speed control signal circuit — Seal 6 EV
This fault code indicates a short to ground or open circuit in the rear HVAC blower motor speed control signal circuit.
Modern BYD vehicles typically use a PWM (pulse-width modulation) signal or an analog voltage signal (0-5V/0-12V) for stepless rear blower speed control.
The HVAC ECU triggers this fault code when it detects an abnormal control signal voltage (a constant 0V short to ground or a high-impedance open circuit) to the rear blower speed control module (power transistor) or blower motor.
This fault results in no airflow from the rear HVAC vents, prevents fan speed adjustment, or restricts operation to a fixed fan speed.
In extreme cases, it triggers the HVAC thermal management protection and limits battery or motor cooling capacity, classifying this as a severe fault.
- 1Internal breakdown of the rear blower speed control module (Power Transistor) causes the control signal wire to short to ground.
- 2Internal short circuit in the rear blower assembly motor pulls down the control signal voltage.
- 3Wiring harness wear or pinching: Damaged harness insulation at the front seat tracks, under the carpet, or in the center tunnel causes the signal wire to short to body ground.
- 4Loose or corroded connector: Poor contact, backed-out terminals, or water ingress and oxidation causing an open circuit at the blower motor connector (usually marked BK45/BK46, etc.) located in the B-pillar, under the rear seat, or inside the air conditioning duct.
- 5A/C controller (HVAC ECU) internal drive circuit fault, preventing normal PWM speed control signal output.
- 1Read freeze frame data: Use the BYD VDS diagnostic tool to record vehicle speed, ambient temperature, and blower duty cycle at the time of the fault to confirm whether the fault is continuous or intermittent.
- 2Visual inspection: Remove the rear center tunnel or roof air conditioning control panel (depending on vehicle configuration). Check the rear blower assembly for abnormal noise, binding, or burn marks. Check if the wiring harness retaining clips are detached.
- 3Circuit measurement: Disconnect the blower speed control module connector. Measure the resistance to ground of the control signal wire (usually a thin wire, possibly blue/green/yellow). A resistance less than 5 Ω indicates a short to ground. Infinite resistance and no continuity to the ECU indicate an open circuit. Measure the blower power supply (constant battery feed) and ground circuits to confirm normal operation.
- 4Component isolation test: Bridge the blower speed control module and supply power directly to the blower to verify smooth motor operation. Use an oscilloscope to check the PWM waveform output from the air conditioning controller (normal: square wave with fixed frequency and variable duty cycle).
- 5Harness repair and replacement: If the wiring harness shows wear, repair it using heat-shrink tubing and re-secure the routing. If the speed control module or blower motor fails, replace the rear blower assembly (spare part numbers vary by vehicle model, e.g., 8102010-X00 for Song MAX). After replacement, perform A/C system self-learning matching (required for some models).
- 6Verification: Clear the fault code. Using the diagnostic tool active test, adjust the rear blower speed from 0% to 100% and verify the data stream changes normally. Perform a 30-minute road test to confirm the fault does not recur.
Song MAX rear AC suddenly lost airflow; wiring harness chafed and shorted to ground.
Qin EV rear blower motor runs only at high speed; speed control signal open circuit.
Tang DM rear blower noisy then faulted; motor short-circuited and damaged the speed control module.
Internal fault in Song MAX HVAC controller caused rear blower motor control failure.
Qin EV rear AC failed after driving through water; connector corroded