This DTC indicates a fault in the drive circuit of the HVAC Recirculation Air Door Actuator motor — Seal 6 EV
This DTC indicates a fault in the drive circuit of the HVAC Recirculation Air Door Actuator motor.
Specifically, a "short to ground" indicates insulation failure between the motor supply line (typically the PWM control line or power line) and the vehicle body ground (GND), causing abnormal current leakage.
An "open circuit" indicates a broken internal motor coil, a loose connector, or a severed wiring harness.
This motor switches the HVAC air door between fresh air and recirculation modes.
A fault prevents mode switching or causes the door to stick in a fixed position, reducing cabin temperature control efficiency.
In extreme cases, this reduces battery thermal management performance (e.g., preventing effective heat dissipation via fresh air mode).
Therefore, the system classifies this as a severe fault.
- 1Recirculation air flap actuator motor internal coil burnt out or short-circuited: Prolonged motor jamming or overloading damages the coil insulation, causing a short to ground or internal open circuit.
- 2Wiring harness and connector fault: Water ingress or poor sealing causes pin corrosion or oxidation at the wiring harness connector near the HVAC unit (usually behind the glove box or at the firewall), or vehicle vibration loosens the male and female terminals.
- 3Mechanical jamming causing motor damage: Foreign matter (such as leaves or accumulated dust) jams the air flap mechanism, or the linkage mechanism deforms, generating excessive motor stall current and ultimately burning out the drive circuit or motor windings.
- 4Air conditioning controller (HVAC ECU) internal fault: Damage to the controller's internal H-bridge drive circuit or MOSFET causes an abnormal output signal (such as a short to ground), triggering a false fault.
- 5Harness wear or damage: Improperly secured wiring harnesses in the engine compartment or instrument panel rub against metal body edges, damaging the insulation and causing a short to ground.
- 1Diagnostic confirmation: Use the BYD VDS diagnostic tool to read all DTCs. Confirm if only B2A4B14 is present or if related fault codes accompany it. Record freeze frame data (such as the motor duty cycle and position feedback values when the fault occurred). Clear the fault codes, operate the fresh air/recirculation switch, and verify if the fault returns.
- 2Visual and connector inspection: Remove the glove box or front passenger lower trim panel and locate the recirculation air flap actuator (usually marked 'REC' or 'Intake'). Check for a loose connector, backed-out pins, and green or white corrosion. Measure the connector terminal-to-ground resistance to check for a short circuit.
- 3Actuator unit inspection: Disconnect the connector and use a multimeter to measure the resistance between the two motor terminals (normal range is typically 30-80Ω; refer to the vehicle repair manual for exact specifications). A resistance of 0Ω indicates a short circuit; infinite resistance indicates an open circuit. Manually move the air flap blade to confirm the mechanical mechanism operates without binding or abnormal noise.
- 4Harness continuity and insulation test: Measure harness continuity (power wire, ground wire, signal wire) from the actuator connector toward the air conditioning controller. Use a megohmmeter or the high-resistance range of a multimeter to measure the insulation resistance of each wire to ground. Resistance must be greater than 1 MΩ. Inspect harness bend points passing through the firewall and hinges.
- 5Controller output check: Connect the diagnostic tool and perform an Actuation Test. Observe the air conditioning controller PWM output waveform and voltage to the recirculation motor. If the controller output is normal but the motor does not operate, replace the actuator. If the controller has no output or the output is shorted to ground, repair or replace the air conditioning controller.
- 6Component replacement and repair: Replace the recirculation air flap actuator motor (on some models, replace the complete flap housing assembly), or repair the damaged wiring harness (seal with heat-shrink tubing and restore the original wrapping). If the flap mechanism binds, remove foreign matter and apply the specified grease.
- 7Calibration and verification: After completing the repair, use VDS to perform the 'Door Motor Calibration' procedure to allow the controller to learn the air flap limit positions. Operate the recirculation/fresh air switch and confirm the air flap moves smoothly without abnormal noise. Read the data stream to confirm the position feedback value changes according to the command (recirculation is usually 0-20%, fresh air is 80-100%). Road test the vehicle to verify the fault code does not recur.