DTC B2A5113 indicates an open circuit in the signal circuit of the A/C system low-pressure line pressure-temperature (PT) sensor — Seal 6 EV
DTC B2A5113 indicates an open circuit in the signal circuit of the A/C system low-pressure line pressure-temperature (PT) sensor.
This sensor typically mounts on the low-pressure line between the evaporator outlet and the compressor inlet.
It monitors low-side refrigerant pressure and temperature in real time, providing a key input signal to the heat pump/A/C control unit (integrated into the right domain controller or A/C controller) for compressor speed regulation, system protection, and thermal management.
When the controller detects the sensor signal voltage continuously exceeding the normal range (typically 0.5-4.5V) or a communication interruption, it sets this open circuit fault.
The system then triggers a protection mechanism and forces the electric compressor to stop, resulting in a complete loss of A/C cooling and heating functions.
In extreme cases, this affects the battery pack cooling circuit and creates an overheating risk.
- 1Internal open circuit in the low-pressure line pressure sensor body (damaged pressure-sensitive element, broken internal solder joint, or open coil)
- 2Poor contact at the sensor connector (terminal back-out, oxidation/corrosion, or loose locking tab causing intermittent connection)
- 3Physical damage to the wiring harness (wear at the firewall pass-through, detached harness retaining clips causing body interference and insulation abrasion, corrosion and breakage after wading)
- 4Severe refrigerant loss in the air conditioning system causes excessively low pressure on the low-pressure side, triggering sensor limit protection (false open circuit).
- 5Control unit sampling circuit fault (damaged internal signal processing chip in the right domain controller or air conditioning controller, open sampling resistor)
- 1Safety preparation: Disconnect the low-voltage battery negative terminal, wait at least 5 minutes to allow the high-voltage system to discharge completely, and wear insulated gloves and safety goggles.
- 2Fault confirmation: Connect the VDS diagnostic tool, read the fault code, record the freeze frame data, and confirm whether the B2A5113 status is active or historical.
- 3Visual inspection: Locate the low-pressure line pressure sensor (located on the low-pressure side of the air conditioning line in the front compartment, usually with a 2-3 pin connector). Inspect the connector for looseness, water ingress, or oxidation, and check the wiring harness for obvious damage or crush marks.
- 4Circuit measurement: Disconnect the sensor connector, turn the ignition switch ON, and measure the connector power supply pin voltage (should be 5V ± 0.25V reference voltage). Measure the signal pin voltage to ground. Turn the ignition switch OFF and measure the sensor resistance (typically several hundred to several thousand ohms at room temperature; refer to the specific vehicle repair manual for standard values).
- 5Harness continuity test: Disconnect the controller-side connector. Use a multimeter to measure continuity between the sensor connector signal pin and the corresponding controller pin. Resistance must be less than 1Ω, and insulation resistance to ground must be greater than 10MΩ.
- 6System pressure verification: Connect a manifold gauge set to the high- and low-pressure service ports and check the static pressure (normal pressure approximates the saturation pressure for the ambient temperature, e.g., 1.5-1.8 MPa at 25°C). A low-pressure side reading near 0 or under vacuum indicates a severe lack of refrigerant.
- 7Component replacement: If the sensor is damaged, replace it with an OEM low-pressure line pressure sensor. (Note: Recover the refrigerant before replacement. After replacement, evacuate the system for at least 30 minutes, then add the standard amount of refrigerant and compressor oil.)
- 8Wiring harness repair: If the circuit is open, repair the wiring harness using waterproof heat-shrink tubing. Re-secure the harness routing to prevent contact with sharp edges.
- 9Function check: Clear the fault code, start the vehicle, and set the air conditioning to maximum cooling mode. Observe the VDS data stream to verify the low-pressure value fluctuates normally with compressor speed (normal range: 0.2-0.5MPa). Confirm the compressor operates normally and the fault code does not return.
BYD Han EV new car AC not cooling (factory refrigerant undercharge)
BYD e2: Intermittent air-con cooling failure (poor connector contact)
BYD Qin Plus EV: Poor cooling performance (damaged sensor unit)
BYD Tang DM intermittent air conditioning failure (connector oxidation)
BYD Song Pro EV air conditioning system fault (wiring harness chafing, open circuit)