DTC B2AB6-4B indicates the Electric A/C Compressor internal temperature sensor detects a temperature outside the normal operating range (typically >120°C or an abnormal temperature rise rate) — Seal 6 EV
DTC B2AB6-4B indicates the Electric A/C Compressor internal temperature sensor detects a temperature outside the normal operating range (typically >120°C or an abnormal temperature rise rate).
This fault indicates the compressor internal thermal protection mechanism triggered.
Electrical insulation failure, mechanical friction overheating, abnormal controller drive, or refrigerant circulation faults can cause this condition.
This fault disables the air conditioning cooling function.
In severe cases, thermal management system anomalies may trigger the 'EV Function Limited' protection mode, restricting the vehicle's pure electric driving capability.
It typically does not affect high-voltage system safety.
- 1Electric compressor internal insulation failure (short to ground or insulation resistance <0.5 MΩ), causing leakage current to convert into heat.
- 2Compressor controller fault causes abnormal drive current or loss of speed control, resulting in overheating.
- 3Scroll plate wear or design defect (early version without sealing ring), causing internal gas blow-by, reduced compression efficiency, and abnormal heat generation.
- 4A/C thermostat / electronic expansion valve fault causes abnormal system pressures (high-side pressure too high / low-side pressure too low), resulting in excessive compressor load.
- 5Refrigerant leak or insufficient POE compressor oil, resulting in poor lubrication and reduced heat dissipation.
- 1Connect the VDS diagnostic tool to read the complete fault codes. Check for accompanying related fault codes such as B2AB573 (operation unsuccessful) and B2AB41D (excessive internal current). Record the compressor speed, current, and temperature data stream.
- 2Use a megohmmeter to measure the insulation resistance between the electric compressor high-voltage terminal and ground. The normal value is >20MΩ. A reading <0.5MΩ confirms insulation failure.
- 3Connect an A/C pressure gauge to check the refrigerant system pressure. Normal high pressure is 1.3-1.5 MPa and normal low pressure is 0.15-0.25 MPa. If the high pressure is abnormally high and the low pressure is abnormally low, check the thermostat and expansion valve.
- 4Check the compressor controller connector and CAN communication wiring. If necessary, perform a controller swap test to rule out an abnormal control signal.
- 5If the above checks are normal, disassemble the compressor, check the scroll plate sealing (for early models, check for a missing sealing ring), and measure the scroll plate clearance.
- 6Replace the faulty component based on the inspection results (compressor assembly/controller/thermostat/scroll plate). Install the improved scroll plate (with sealing ring) and add the specified POE refrigerant oil.
- 7After repair, evacuate the system, charge with the standard amount of refrigerant (usually 450-550g), run the self-learning procedure, and monitor the compressor internal temperature data stream.
Compressor insulation failure caused abnormal temperature
Compressor controller fault caused recurring temperature abnormalities
Air conditioning system combined fault (thermostat and controller)
Scroll plate design defect causes abnormal internal temperature