DTC B2AB997 indicates the electric air-conditioning compressor (E-Compressor) operating load exceeds the system-calibrated safety threshold — Seal 6 EV
DTC B2AB997 indicates the electric air-conditioning compressor (E-Compressor) operating load exceeds the system-calibrated safety threshold.
The compressor controller or vehicle control unit (VCU) triggers this fault in the BYD Qin EV thermal management system when it detects a compressor drive current continuously exceeding the rated value (typically >15-20A, depending on operating conditions), an abnormal drop in speed feedback (stall risk), or an abnormal rise in torque demand.
The system then registers an 'excessive load'.
This protective fault prevents compressor mechanical damage, high-voltage circuit overload, or thermal management system failure.
The fault can reduce air-conditioning cooling capacity and automatically shut down the compressor.
Extreme cases may trigger high-voltage interlock protection, affecting battery thermal management functions.
- 1Internal mechanical binding or lubrication failure in the electric compressor: scroll plate wear, bearing seizure, or degraded or insufficient refrigerant oil, causing increased mechanical resistance torque.
- 2Abnormal A/C system pressure: high condenser pressure (dirty or blocked condenser, cooling fan failure, high ambient temperature), low evaporator pressure (expansion valve failure, blocked line), or excessive refrigerant charge (excess liquid refrigerant causes liquid slugging risk)
- 3High-voltage power supply system malfunction: unstable traction battery voltage (undervoltage or overvoltage), poor contact in the high-voltage wiring harness (burnt or loose connectors causing increased resistance), compressor controller (IPM) power module fault
- 4Poor heat dissipation in the thermal management system: severely contaminated front-end module (condenser + radiator), abnormal electric fan speed (PWM signal fault or motor aging), or restricted coolant flow causing compressor overheating.
- 5Control strategy or sensor fault: compressor phase current sensor drift, CAN bus communication fault causing the VCU to misjudge the load, or incorrect software calibration parameters.
- 1Fault Confirmation and Data Reading: Use the VDS2000/VDS3000 diagnostic tool to read all fault codes and confirm if B2AB997 is a current fault. Read the data stream, focusing on compressor current (A), speed (rpm), duty cycle (%), high-voltage bus voltage (V), A/C high-side pressure (MPa), and condenser outlet temperature (°C).
- 2High-voltage safety check: Perform the high-voltage power-down procedure. Wear insulated gloves. Measure the insulation resistance of the compressor high-voltage wiring harness (standard value ≥20MΩ). Inspect high-voltage connectors (B23/B24) for burn damage or backed-out pins. Measure the contact resistance (<0.1Ω).
- 3A/C system pressure check: Connect the manifold gauge set. Check the static pressure (approximately 1.0-1.2 MPa at 25°C). Check the dynamic high-side pressure (1.5-2.5 MPa, depending on ambient temperature) and low-side pressure (0.15-0.25 MPa) to verify if the high-side pressure is excessively high or the low-side pressure is excessively low.
- 4Compressor mechanical inspection: Disconnect high-pressure and low-pressure lines. Check compressor turning resistance (manually turn the clutch plate; it must rotate smoothly without binding, resistance torque <3N·m). Check refrigerant oil condition (colour, impurities, quantity). If necessary, use dedicated equipment to test compressor insulation (>20MΩ) and coil resistance (three-phase balance, deviation <10%).
- 5Thermal management cooling system inspection: Clean the condenser surface (use a dedicated cleaning agent to avoid damaging the cooling fins); check the electric fan low-speed and high-speed operation (low speed approx. 1000rpm, high speed approx. 2000rpm); check the coolant level and circulation (electric water pump operation).
- 6Control module and wiring inspection: Measure the compressor controller low-voltage power supply (12V±0.5V) and ground (<0.1Ω). Check the CAN-H and CAN-L voltages (2.5V±0.5V) and waveforms (dominant level: CAN-H 3.5V / CAN-L 1.5V) to rule out short or open circuits in the wiring.
- 7Repair verification: After repairing or replacing the faulty component, draw a vacuum (hold at -0.1 MPa for 30 minutes) and charge the refrigerant as specified (R134a, usually 550-650 g). Perform the compressor run-in procedure (gradually increase speed). Monitor the data stream during a road test to confirm the current stabilizes within the normal range (5-12 A) and the fault code does not recur.
Qin EV 2019: Worn compressor scroll plate causing excessive load
Severely clogged condenser caused excessive high-side pressure
Poor contact in high-voltage wiring harness caused abnormal load.
Refrigerant overcharge causing liquid slugging risk
Compressor controller IPM module fault