B2AB997

DTC B2AB997 indicates the electric air-conditioning compressor (E-Compressor) operating load exceeds the system-calibrated safety threshold — Seal 6 EV

Thermal Management System

DTC B2AB997 indicates the electric air-conditioning compressor (E-Compressor) operating load exceeds the system-calibrated safety threshold.

The compressor controller or vehicle control unit (VCU) triggers this fault in the BYD Qin EV thermal management system when it detects a compressor drive current continuously exceeding the rated value (typically >15-20A, depending on operating conditions), an abnormal drop in speed feedback (stall risk), or an abnormal rise in torque demand.

The system then registers an 'excessive load'.

This protective fault prevents compressor mechanical damage, high-voltage circuit overload, or thermal management system failure.

The fault can reduce air-conditioning cooling capacity and automatically shut down the compressor.

Extreme cases may trigger high-voltage interlock protection, affecting battery thermal management functions.

The B2AB997 fault code on the Seal 6 EV indicates the electric air-conditioning compressor is working harder than the safe calibrated limit. Severity is medium, as cooling may be reduced and the compressor may shut down to prevent damage. Common causes include internal compressor wear or binding, and abnormal A/C pressure from a blocked condenser, fan fault, or refrigerant issue. Visit an authorised dealer for diagnosis and repair. Typical repair cost data is available.
5
Cases Logged
5
Causes
  • 1Internal mechanical binding or lubrication failure in the electric compressor: scroll plate wear, bearing seizure, or degraded or insufficient refrigerant oil, causing increased mechanical resistance torque.
  • 2Abnormal A/C system pressure: high condenser pressure (dirty or blocked condenser, cooling fan failure, high ambient temperature), low evaporator pressure (expansion valve failure, blocked line), or excessive refrigerant charge (excess liquid refrigerant causes liquid slugging risk)
  • 3High-voltage power supply system malfunction: unstable traction battery voltage (undervoltage or overvoltage), poor contact in the high-voltage wiring harness (burnt or loose connectors causing increased resistance), compressor controller (IPM) power module fault
  • 4Poor heat dissipation in the thermal management system: severely contaminated front-end module (condenser + radiator), abnormal electric fan speed (PWM signal fault or motor aging), or restricted coolant flow causing compressor overheating.
  • 5Control strategy or sensor fault: compressor phase current sensor drift, CAN bus communication fault causing the VCU to misjudge the load, or incorrect software calibration parameters.
  • 1
    Fault Confirmation and Data Reading: Use the VDS2000/VDS3000 diagnostic tool to read all fault codes and confirm if B2AB997 is a current fault. Read the data stream, focusing on compressor current (A), speed (rpm), duty cycle (%), high-voltage bus voltage (V), A/C high-side pressure (MPa), and condenser outlet temperature (°C).
  • 2
    High-voltage safety check: Perform the high-voltage power-down procedure. Wear insulated gloves. Measure the insulation resistance of the compressor high-voltage wiring harness (standard value ≥20MΩ). Inspect high-voltage connectors (B23/B24) for burn damage or backed-out pins. Measure the contact resistance (<0.1Ω).
  • 3
    A/C system pressure check: Connect the manifold gauge set. Check the static pressure (approximately 1.0-1.2 MPa at 25°C). Check the dynamic high-side pressure (1.5-2.5 MPa, depending on ambient temperature) and low-side pressure (0.15-0.25 MPa) to verify if the high-side pressure is excessively high or the low-side pressure is excessively low.
  • 4
    Compressor mechanical inspection: Disconnect high-pressure and low-pressure lines. Check compressor turning resistance (manually turn the clutch plate; it must rotate smoothly without binding, resistance torque <3N·m). Check refrigerant oil condition (colour, impurities, quantity). If necessary, use dedicated equipment to test compressor insulation (>20MΩ) and coil resistance (three-phase balance, deviation <10%).
  • 5
    Thermal management cooling system inspection: Clean the condenser surface (use a dedicated cleaning agent to avoid damaging the cooling fins); check the electric fan low-speed and high-speed operation (low speed approx. 1000rpm, high speed approx. 2000rpm); check the coolant level and circulation (electric water pump operation).
  • 6
    Control module and wiring inspection: Measure the compressor controller low-voltage power supply (12V±0.5V) and ground (<0.1Ω). Check the CAN-H and CAN-L voltages (2.5V±0.5V) and waveforms (dominant level: CAN-H 3.5V / CAN-L 1.5V) to rule out short or open circuits in the wiring.
  • 7
    Repair verification: After repairing or replacing the faulty component, draw a vacuum (hold at -0.1 MPa for 30 minutes) and charge the refrigerant as specified (R134a, usually 550-650 g). Perform the compressor run-in procedure (gradually increase speed). Monitor the data stream during a road test to confirm the current stabilizes within the normal range (5-12 A) and the fault code does not recur.
BYD DTC AI Analysis

Qin EV 2019: Worn compressor scroll plate causing excessive load

Vehicle: 2019 BYD Qin EV, 85,000 km. Symptoms: Approximately 5 minutes after turning on the AC, the vents blew warm air and the thermal management warning light illuminated. Retrieved DTC B2AB997. Diagnosis: Live data showed compressor current spiking to 25 A (normal ≤15 A) before the system shut down. Static pressures read normal, but dismantling the compressor revealed severe wear to the scroll plates, with internal metal debris causing mechanical seizure. Repair: Replaced the electric compressor assembly. Flushed the AC lines, condenser and evaporator with dedicated cleaner, and replaced the desiccant. Recharged the system with refrigerant and compressor oil (SP-A2 oil, 150 ml) to specification. Fault resolved.
BYD DTC AI Analysis

Severely clogged condenser caused excessive high-side pressure

Vehicle: Qin EV 2019, 60,000 km, used year-round on construction sites. Symptoms: AC kept shutting down in hot summer weather. Scanner logged DTC B2AB997. Diagnosis: Data stream showed 38°C ambient with condenser outlet at 85°C (normal <65°C). High-side pressure read 3.2 MPa (normal 2.0–2.5 MPa) and compressor current stayed above 18 A. Found the condenser completely clogged externally with mud and willow fluff. The cooling fan ran at high speed but couldn't dissipate heat properly. Fix: Thoroughly cleaned the condenser fins (used a fin comb to straighten deformed fins), replaced the cabin filter, and cleaned the gap between the radiator and condenser. Cleared the codes; system returned to normal.
BYD DTC AI Analysis

Poor contact in high-voltage wiring harness caused abnormal load.

Vehicle: BYD Qin EV 2019, accident-repaired vehicle. Symptom: Intermittent AC cooling failure, intermittent DTC B2AB997. Diagnosis: Data stream showed high voltage bus voltage dropping instantly from 420V to 380V when the compressor engaged, with large current fluctuations. Inspection found burn marks inside high voltage harness connector B23 (front compartment high voltage distribution box to compressor). Contact resistance measured 2.3Ω (normal <0.05Ω), causing insufficient input voltage to the compressor controller. The controller increased current to maintain power, triggering overload protection. Repair: Replaced high voltage harness assembly, cleaned contacts and applied conductive paste, tightened connector. Fault resolved.
BYD DTC AI Analysis

Refrigerant overcharge causing liquid slugging risk

Vehicle: Qin EV 2019. Fault appeared after a workshop topped up the refrigerant. Symptoms: Compressor noise when the AC turned on, followed by DTC B2AB997 and shutdown. Diagnosis: Recovery yielded 850g of refrigerant (standard: 600g). High-side pressure hit 2.8MPa at 25°C ambient. Compressor drew 16A. Liquid refrigerant entered the compressor before fully evaporating, causing liquid slugging and high mechanical load. Solution: Recovered all refrigerant and recharged to the standard 600g±25g. Replaced the receiver drier (liquid may have entered). Compressor load returned to normal.
BYD DTC AI Analysis

Compressor controller IPM module fault

Vehicle: Qin EV 2019, 42,000 km. Symptoms: AC not cooling at all. Throwing B2AB997 and B2AB809 (compressor drive fault). Diagnosis: Measured compressor three-phase winding resistance balanced at 0.8 Ω; insulation normal. Controller low-voltage supply and signals normal. Internal IPM (Intelligent Power Module) in the controller failed, distorting the output current waveform and causing the phase current sensor to detect abnormally high current. Repair: Replaced compressor controller (some variants require the complete compressor assembly depending on configuration). Flashed control program to V2.3.1. Fault resolved.
Common problems reported for Seal 6 EVSeal 6 EV overview →
Data confidence: Official This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.