This DTC indicates the IPB (Intelligent Integrated Braking System) detected an abnormal main power supply and automatically switched to UBB (Ultracapacitor Backup Battery) power mode to maintain basic braking functions — Seal 6 EV
This DTC indicates the IPB (Intelligent Integrated Braking System) detected an abnormal main power supply and automatically switched to UBB (Ultracapacitor Backup Battery) power mode to maintain basic braking functions.
Common causes include low voltage in the 12V low-voltage system (<9V), poor contact in the power supply circuit, abnormal DC-DC converter output, or an internal IPB power management fault.
In this mode, the system limits or disables advanced functions such as ABS, ESC, and Automatic Emergency Braking, retaining only basic hydraulic braking capability.
The brake pedal may feel harder.
This Level 2 fault affects driving safety.
- 112V low-voltage battery aging, discharge, or capacity degradation causes the voltage to fall outside the IPB operating threshold (usually <9V or >16V).
- 2Poor contact in the IPB power supply circuit, including backed-out pins, oxidation, or burn damage at the connectors between the front compartment power distribution box and the IPB (GJK01, etc.), or loose ground points (G301/G08).
- 3Abnormal or fluctuating DC-DC converter output voltage (hybrid/pure electric models) causes unstable low-voltage power supply, failing to maintain IPB main power supply requirements.
- 4IPB internal power management module or voltage sampling circuit fault causing false reporting of power mode switching.
- 5Vehicle charging system fault (generator/DC-DC) causes battery voltage to drop continuously while driving, triggering backup power supply protection.
- 1Use the BYD VDS diagnostic tool to read complete fault codes and freeze frame data. Check the actual supply voltage (Battery_Voltage), backup power supply status, and historical fault records in the IPB data stream.
- 2Check 12V low-voltage battery status: Measure static voltage (should be ≥12.4V) and dynamic voltage during startup/driving (should not be <9V). If necessary, perform a battery State of Health (SOH) test and charging test.
- 3Check the IPB power supply circuit: Check the IPB fuse in the front compartment power distribution box (usually F4/9 or F1/16). Measure the voltage and voltage drop at the power supply pins of connectors such as GJK01/G2K01 (should be <0.3V). Inspect the pins for backing out, burning, or water ingress.
- 4Check ground points: Tighten and clean key ground points such as G301 (left side of front compartment) and G08 (left side of dashboard). Measure circuit resistance (should be <0.1Ω).
- 5For hybrid/pure electric vehicles, check the DC-DC converter output voltage stability (should stabilize at 13.5-14.5V), eliminate low-voltage charging system faults, and update the VCU/BMS software if necessary.
- 6If the external power supply and wiring are normal but the IPB still reports a fault, replace the IPB electro-hydraulic module assembly, bleed the brake system, calibrate the pedal position, and perform an ESC function test.
Qin DM no power due to invalid battery voltage signal
Song Pro DM-i cuts out while driving and reports voltage fault
Han EV excessive sleep current causing battery discharge and voltage fault
Tang DM Starting Difficulty and Communication Fault with P056023
Dolphin instrument panel battery level fault and range fluctuation