BYD technical documentation defines DTC B2A2013 as "Evaporator Temperature Sensor Circuit Open," rather than a generic "cabin temperature sensor" fault — Seal U
BYD technical documentation defines DTC B2A2013 as "Evaporator Temperature Sensor Circuit Open," rather than a generic "cabin temperature sensor" fault.
Located inside the HVAC evaporator case, this sensor monitors the evaporator core surface temperature in real time.
It sends critical feedback to the air conditioning controller (AC ECU) to prevent evaporator icing, regulate compressor displacement, and control the electronic expansion valve opening.
The AC ECU logs an open circuit fault when it detects the sensor signal voltage remaining above 4.95V or below 0.05V (outside the valid range).
This fault triggers the A/C system protection logic, which forcibly disengages the compressor electromagnetic clutch or stops the electric compressor, completely disabling A/C cooling.
Because BYD New Energy Vehicles (NEVs) deeply integrate the A/C and battery thermal management systems (typically incorporating the battery chiller into the A/C refrigerant circuit), this fault can cascade into a battery cooling system failure.
This causes abnormal vehicle thermal management and may restrict power output.
- 1Internal open circuit in the evaporator temperature sensor or thermistor characteristic drift, preventing the sensor from generating a valid temperature-resistance signal.
- 2Sensor wiring harness worn, broken, or crushed at stress concentration points such as the firewall wiring grommet and instrument panel frame mounting points.
- 3Oxidation, corrosion, or poor contact of the sensor connector plug pins due to evaporator condensate leakage, floor water ingress, or water intrusion during car washing.
- 4Loose wiring harness retaining clip causes movement during driving. Prolonged strain breaks the wire at the connector base (intermittent open circuit).
- 5Air conditioning controller internal signal sampling circuit fault (e.g., open voltage divider resistor or shorted filter capacitor), preventing correct identification of sensor signals.
- 1Use a dedicated diagnostic tool (such as VDS2000 or Launch X-431) to read the air conditioning system fault codes, confirm B2A2013 is present, and record the freeze frame data (abnormal ambient and evaporator temperature values are usually -40°C or a fixed high value).
- 2Enter data stream mode and monitor the 'evaporator temperature sensor' value in real time. Turn on the air conditioning. If the value does not change or remains at an extreme value (-40°C/120°C), confirm the signal is abnormal.
- 3Remove the front passenger glove box or lower dashboard trim panel. Locate the evaporator temperature sensor (usually a two-wire NTC thermistor on the evaporator housing). Visually inspect the connector for looseness, water ingress, or corrosion.
- 4Disconnect the connector and measure the sensor resistance. At 25°C ambient temperature, the standard value is 1.8-2.5kΩ. Warm the sensor by hand; the resistance must decrease as the temperature rises (negative temperature coefficient characteristic). If the resistance is infinite or remains unchanged, replace the sensor.
- 5Measure harness side voltage: With the ignition switch ON and the connector disconnected, measure the harness terminals for a 5V reference voltage (supplied by the AC ECU) and a ground circuit. If the voltage is 0V or 12V, check the power supply/ground wiring.
- 6Measure harness continuity between the sensor and the AC ECU using a multimeter set to resistance. The standard resistance must be less than 1Ω. Specifically inspect the firewall wiring grommet and bends in the floor harness protective sleeve. Repair any open circuits and install a wear-resistant protective sleeve.
- 7If the wiring harness and sensor are normal, measure continuity between the corresponding AC ECU pin and the sensor. If the ECU side does not output a 5V reference voltage, this indicates an internal A/C controller fault. Replace or repair the controller.
- 8After repair, reconnect all connectors, clear the fault code, and run the 'Air Conditioning System Self-Diagnosis' or 'Component Test' function to confirm the evaporator temperature data stream returns to normal (typically 2-10°C, varying with operating conditions).
- 9Perform a 30-minute road test to verify if the fault code returns. Check the A/C cooling performance and verify normal operation of the battery cooling system linkage.
BYD Qin EV300 AC not cooling — oxidized connector causing intermittent open circuit
BYD Tang DM intermittent AC shutdown – sensor corroded by condensate
BYD Song Pro EV compressor not working — firewall wiring harness chafed through, open circuit
Water in BYD Han EV floor corroded sensor connector