This DTC indicates a phase loss in the internal three-phase permanent magnet synchronous motor of the electric A/C compressor (E-Compressor) — Seal U
This DTC indicates a phase loss in the internal three-phase permanent magnet synchronous motor of the electric A/C compressor (E-Compressor).
When the compressor controller (inverter) supplies power to the motor U/V/W three-phase windings, it detects a loss of at least one phase current or a voltage drop exceeding the threshold.
Open windings, open high-voltage harnesses, or damaged IGBT power modules typically cause this condition.
This fault prevents the compressor from generating effective torque and forces it to stop, which disables the A/C cooling and heating functions and triggers the thermal management system derating protection.
In vehicles like the BYD Qin EV, battery cooling relies on the A/C refrigerant circuit; therefore, this fault may indirectly raise the battery pack temperature and limit charge and discharge power.
- 1Compressor high-voltage wiring harness connector burnt or loose: The three-phase high-voltage plug (usually located on top of the compressor) generates high temperatures due to long-term vibration or excessive contact resistance, causing pin ablation and recession that results in an open circuit in one phase.
- 2Electric compressor controller (IPM module) fault: Breakdown of the upper and lower bridge arms in one or more phases of the built-in IGBT power module, or drive circuit damage, prevents the output of a complete three-phase sine wave voltage.
- 3Compressor motor winding burnt out: Insulation breakdown, overheating, or overload causes an open circuit (infinite resistance) or inter-turn short circuit in one phase of the internal three-phase motor winding.
- 4High-voltage power distribution box compressor fuse blown or relay stuck: A single phase of the 500V/20A fast-acting fuse in the high-voltage supply circuit blew, or burned high-voltage contactor contacts cause a three-phase power supply imbalance.
- 5Abnormal low-voltage control signal: CAN communication fault between the thermal management system (TMS) controller and the compressor controller, or an abnormal 12V control power supply/enable signal causing the controller to falsely detect a phase loss.
- 1Diagnostic scan: Use VDS2000/3000 to read all fault codes. Check for accompanying codes B2AB2-49 (IPM fault), B2AB3-11 (compressor overcurrent), or high-voltage interlock faults. Record freeze frame data from the time of the fault (bus voltage, three-phase current values).
- 2High-voltage safety check: Disconnect the low-voltage battery negative terminal, wait 5 minutes, put on insulated gloves, remove the compressor high-voltage service switch, and verify no residual voltage remains in the high-voltage system (<60V DC).
- 3High-voltage wiring harness inspection: Check the compressor three-phase high-voltage connector (orange-yellow) for signs of burning, terminal back-out, or water ingress. Use a multimeter to measure the continuity of the three-phase wiring harness at the connector end (U-V, V-W, W-U); resistance must be <1Ω. Use a 1000V megohmmeter to measure the insulation resistance between the three phases and the housing; resistance must be >500MΩ.
- 4Motor winding inspection: Disconnect the compressor high-voltage connector and directly measure the three-phase DC resistance at the compressor terminals (U-V, V-W, W-U). Normal resistance is 0.5-2.0Ω with a three-phase imbalance rate <5%. If any phase reads infinite resistance, the motor winding has an open circuit; replace the compressor assembly.
- 5Controller function check: Restore low-voltage power supply and use the diagnostic tool to perform the compressor Active Test. Use an oscilloscope to check the three-phase voltage waveforms at the controller output terminals. The waveforms must show symmetrical three-phase sine waves. If any phase has no waveform output, the controller is faulty. Replace the compressor controller or the entire compressor assembly (BYD usually provides the complete assembly).
- 6System reset verification: After repair, clear the fault code. Vacuum-fill the thermal management system and recharge the refrigerant. Perform a 30-minute air conditioning operation test, monitor the three-phase current balance (current difference between phases <10%), and confirm the fault code does not return.
Burnt high-voltage plug on Qin EV compressor causing intermittent phase loss
Damaged electric compressor IGBT module triggered phase loss protection
Refrigerant leak caused compressor overheating and phase loss
High-voltage distribution box relay contacts burned