This fault code indicates a functional failure of the No — Atto 3
This fault code indicates a functional failure of the No. 3 IGBT (Insulated Gate Bipolar Transistor) driver chip in the thermal management system.
In BYD Qin series new energy vehicles, the A/C PTC (Positive Temperature Coefficient) heater uses an IGBT module for high-power PWM modulation control, where "3#" refers to the third-phase drive channel or the third IGBT unit.
The IGBT driver chip converts low-voltage logic signals from the controller into high-voltage, high-frequency pulse signals to drive the IGBT gate, precisely regulating PTC heater power (0-100% duty cycle control).
This fault occurs when the driver chip fails to output the normal gate drive voltage (typically a +15V/-8V push-pull signal), or when the chip’s internal desaturation protection or overcurrent protection triggers abnormally, preventing the IGBT from conducting or forcing it to remain off.
This directly causes partial or complete PTC heater failure, affecting cabin heating.
In low-temperature environments, it also disables battery pack preheating, potentially triggering a vehicle thermal management fault and limiting power output.
Qin Pro DM PTC heater IGBT driver chip overheated and burnt out
Poor contact in the Qin EV300 PTC drive wiring harness caused IGBT failure.
Drive mismatch fault after aftermarket PTC replacement on Qin Pro DM
Qin EV300 air conditioning controller drive power fault triggered cascade failures