B177D

DTC B177D indicates the airbag system (SRS) detects a 0 Ω circuit resistance in the right middle-row (typically second-row right) seat belt pretensioner — Atto 8

Safety System

DTC B177D indicates the airbag system (SRS) detects a 0 Ω circuit resistance in the right middle-row (typically second-row right) seat belt pretensioner.

As a pyrotechnic actuator, the seat belt pretensioner squib normally has a resistance of 1.5-3.0 Ω (typically 2.0 Ω).

A 0 Ω resistance indicates a short circuit.

Potential causes include an internal pretensioner squib short, a wiring harness short to ground, or a short between connector terminals.

This fault causes the SRS ECU to determine the pretensioner is in an unsafe state.

During a collision, the pretensioner may fail to deploy and tension the seat belt, or the short circuit may force the airbag system into a degraded mode, compromising overall passive safety performance.

5
Cases Logged
BYD DTC AI Analysis

Worn right second-row seat wiring harness caused short circuit in Song MAX

A 2019 BYD Song MAX logged DTC B177D. Inspection found that when the right second-row seat was fully forward, the seatbelt pretensioner harness interfered with the metal edge of the seat rail. Prolonged friction wore through the insulation, exposing copper cores that contacted the body and shorted to ground. Repair: Repaired the damaged harness (3 wires, one completely severed), added corrugated tubing for protection, and repositioned the harness clips to eliminate interference throughout the full seat travel. After clearing the code, resistance returned to 2.1Ω.
BYD DTC AI Analysis

Tang DM-i pretensioner connector water ingress corrosion

2021 Tang DM-i logged DTC B177D after the rainy season. Removed the right middle row seat and found green corrosion inside the pretensioner connector at the seat base. Moisture between the pins caused a micro-short; resistance measured near 0Ω. Root cause: Water entered when the vehicle waded through water above the door sill, or through a blocked sunroof drain tube. Repair: Cleaned the connector terminals, removed corrosion with electronic cleaner, applied conductive grease, and replaced the waterproof seal ring. Recommend checking the other seat connectors on the same side.
BYD DTC AI Analysis

Yuan EV Seatbelt Pretensioner Internal Squib Short Circuit Replacement Case

2019 BYD Yuan EV set DTC B177D after collision repairs. The right second-row seatbelt pretensioner took a side impact without deploying. Disassembly revealed the pretensioner squib's bridgewire had deformed and shorted from the impact, measuring 0.2Ω. Pretensioners are single-use safety components; internal damage can cause electrical faults even without deployment. Solution: Replaced the right second-row seatbelt assembly (including pretensioner). New part measured 1.8Ω and the fault cleared. Check resistance on all seatbelt pretensioners when repairing accident-damaged vehicles.
BYD DTC AI Analysis

Qin Pro: Human-induced fault after repair

2020 Qin Pro developed DTC B177D following replacement of the right-hand second-row seat trim. Inspection traced the fault to the technician pinching the pretensioner harness in the seat frame gap during seat removal and installation; this went unnoticed during reassembly, crushing the harness and shorting it to the frame. The technician had also used a standard multimeter on the resistance setting to directly measure the pretensioner—while not the direct cause, this presented a safety risk. Technicians freed the trapped harness, repaired the damaged section, dressed burrs on the seat frame, and fitted protective sleeving to the harness. Staff received training on SRS system operating standards.
BYD DTC AI Analysis

Multi-model SRS ECU software false positive fix

Multiple BYD models (2021 Tang, 2019 Song MAX, etc.) have an algorithm defect in specific batches of SRS ECU software. Cold starts below -10°C trigger false B177D codes. Measured pretensioner resistance is 2.0Ω (normal); harness shows no shorts. VDS freeze frame data confirms the fault only occurs at cold start. Solution: Update SRS control unit software to the latest version (confirm version number for the specific model). Fault clears after upgrade. This is a software false fault; no hardware replacement needed.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.