DTC B2AB0-49 indicates an abnormality in the electric A/C compressor current sampling circuit — Atto 8
DTC B2AB0-49 indicates an abnormality in the electric A/C compressor current sampling circuit.
In electric compressors driven by a three-phase permanent magnet synchronous motor (PMSM), the controller (MCU) monitors the motor phase currents (U/V/W phases) in real time via a Hall effect sensor or precision shunt resistor for field-oriented control (FOC) and overcurrent protection.
This fault indicates the sampling signal exceeds the valid threshold (open circuit, short circuit, or short to power/ground).
Consequently, the compressor controller cannot accurately read the motor current value and triggers a protection mechanism to stop the compressor, impairing A/C cooling and battery thermal management functions.
This is a hardware-level circuit fault, not a software logic error.
Qin PRO EV compressor Hall sensor intermittent open circuit
Qin EV300 compressor controller board sampling resistor burnt out
热管理线束磨损导致信号干扰
Insufficient refrigerant caused abnormal current fluctuations in the compressor.
Software false positive (phantom DTC)