This fault code indicates the internal drive current of the thermal management system electric scroll compressor (E-Compressor) exceeds the safety threshold set by the MCU (microcontroller unit) (typically peak current >45A or sustained RMS current >15A) — Atto 8
This fault code indicates the internal drive current of the thermal management system electric scroll compressor (E-Compressor) exceeds the safety threshold set by the MCU (microcontroller unit) (typically peak current >45A or sustained RMS current >15A).
This hardware-level protection fault indicates the compressor permanent magnet synchronous motor (PMSM) or its integrated controller (including the IPM intelligent power module) detects abnormal current consumption.
During compressor start-up or operation, the controller triggers this fault if Hall sensors detect a three-phase current imbalance exceeding 10%, or if the instantaneous DC bus current exceeds the calibrated limit (approximately 22-25A) for over 100ms.
The compressor stops immediately to protect the IGBT power devices, affecting cabin air conditioning cooling/heating and battery pack liquid cooling functions.
A prolonged fault may burn out the compressor controller or blow the high-voltage fuse (typically 30A-40A).
Qin EV compressor winding insulation degradation causes intermittent overcurrent
Ice blockage in refrigerant system triggered compressor overload protection
Burned high voltage contactor caused abnormal compressor current.
Drift in the compressor controller sampling resistor caused false fault reports.