U011187

DTC U011187 indicates the Body Control Computer (BCC) failed to receive CAN message ID 0x44A (hexadecimal) from the Battery Management System (BMS) via the air conditioning controller (acting as a gateway/relay node) — Qin Plus

Thermal Management System

DTC U011187 indicates the Body Control Computer (BCC) failed to receive CAN message ID 0x44A (hexadecimal) from the Battery Management System (BMS) via the air conditioning controller (acting as a gateway/relay node).

This battery status information frame typically contains key thermal management parameters, including total battery voltage, total current, SOC, highest/lowest cell voltage, and temperature.

This fault represents a gateway communication interruption between the thermal management sub-network and the body control network.

The interruption prevents the BCC from obtaining real-time battery status to coordinate thermal management actuators, such as air conditioning compressor speed, PTC heating, and cooling fans.

Consequently, this can cause battery temperature control failure, range estimation deviation, or abnormal coordination between the air conditioning system and battery cooling.

4
Cases Logged
BYD DTC AI Analysis

BYD Tang ACC Fault with U011187 — Burnt Ground Wire with Loose Connection

The ACC system failed and the instrument cluster displayed a communication error. Diagnosis revealed multiple communication faults including U011587 and U101387 in addition to U011187 (Lost Communication with BMS). Inspection of the MPC connector found the 5# ground wire bolt loose, causing the contact to burn. Grinding and retightening the ground point cleared the fault codes and restored ACC function. Poor grounding causes communication errors across multiple control modules, triggering U011187.
Original source ↗
BYD DTC AI Analysis

BYD e5 taxi intermittent loss of power while driving — VCU communication fault cluster

The vehicle intermittently displayed "Check Powertrain System" while driving and the OK light went out; it recovered after powering off and waiting. VDS scan showed the Battery Manager reporting communication faults with the leakage sensor, active discharge module and A/C; the Drive Motor Controller reporting a communication fault with the Vehicle Control Unit; and the Vehicle Control Unit reporting U011187 (communication fault with Battery Manager), U012887, U029187 and over a dozen other communication faults. Checked the wiring harness connections at the Vehicle Control Unit; they were secure but CAN line integrity needs further troubleshooting.
Original source ↗
BYD DTC AI Analysis

BYD e2 intermittent failure to enter OK mode — broken CAN High pin in floor wiring harness

Vehicle occasionally failed to enter Ready mode, with the cooling fan running continuously and difficulty shutting down. VDS detected multiple communication faults: U011187, U024E87, and U012187. Measurements of the Comfort and Powertrain CAN buses revealed abnormal termination resistance on the Powertrain network. Further inspection found that pin 15 (CAN High) of the floor harness GJK04 module had broken, causing an intermittent connection that left CAN High pin 5 of BJG02 without voltage. Repaired the CAN High circuit by bridging the break and restored the pin connection. Fault resolved.
Original source ↗
BYD DTC AI Analysis

BYD U011187 General Diagnosis — Comprehensive Analysis of Wiring and Module Faults

DTC U011187 (Lost Communication With BMS) – General Diagnostic Procedure: Common causes include poor harness connections (loose or corroded vehicle wiring interrupting signal transmission), sensor failures (damaged vehicle status sensors affecting communication), and control module faults. Check all related harness connections for looseness or corrosion. Replace battery management sensors or the BMS control module as required. Clear the DTC with a diagnostic scan tool, then perform matching and relearn procedures.
Original source ↗
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.