This DTC indicates the electric air conditioning compressor (EAC) high-voltage power supply circuit detects an input voltage below the normal operating threshold (typically below 250V-300V, depending on the vehicle software version) — Seal 6 EV
This DTC indicates the electric air conditioning compressor (EAC) high-voltage power supply circuit detects an input voltage below the normal operating threshold (typically below 250V-300V, depending on the vehicle software version).
In BYD thermal management systems, the high-voltage battery (300-750V DC) directly powers the electric compressor, and the controller monitors the high-voltage side voltage in real time.
Upon detecting sustained undervoltage, the system limits or stops compressor operation to protect the compressor inverter module (IPM), causing air conditioning cooling/heating failure or degraded thermal management performance.
BMS power limitations or insulation faults typically accompany this fault, which essentially indicates an abnormality in the high-voltage power distribution circuit or battery pack energy management.
BYD Qin EV300 air conditioning not cooling with DTC B123C16
BYD Qin Pro DM thermal management fault caused power restriction
Intermittent B123C16 fault caused by battery cell undervoltage
Electric compressor controller false fault