B160B-00

DTC B160B-00 indicates the SRS (Supplemental Restraint System) ECU detects the driver's front airbag (steering wheel airbag) igniter circuit resistance is below the calibrated threshold (usually <1 — Seal 6 EV

Safety System

DTC B160B-00 indicates the SRS (Supplemental Restraint System) ECU detects the driver's front airbag (steering wheel airbag) igniter circuit resistance is below the calibrated threshold (usually <1.0Ω).

Normal airbag igniter resistance is 2.0-3.0Ω.

Low resistance usually indicates a circuit short to ground, an internal short in the airbag module, or abnormal connector continuity.

This fault causes the SRS ECU to register an abnormal airbag circuit.

The airbag may fail to deploy during a collision or deploy unintentionally while driving.

Consequently, the system illuminates the airbag warning lamp and disables the airbag function.

5
Cases Logged
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD Qin EV300 clock spring internally shorted, causing lower than normal resistance

The airbag light was on steady when the vehicle arrived. Pulled DTC B160B-00. Inspected and found the steering wheel felt notchy when turned. Disconnected the airbag connector and measured only 0.2 ohms across the clock spring, with both terminals showing continuity to ground. Disassembled the clock spring and found the ribbon cable insulation damaged, causing a short. Replaced with a genuine clock spring (part number: KJ-3479010). Resistance returned to 2.3 ohms and the fault cleared.
BYD DTC AI AnalysisFrom Chinese market (translated)

Qin 80: Airbag connector shorted due to water ingress after wading

The vehicle drove through water approximately 40cm deep. Afterwards, the airbag warning light illuminated. The scan tool showed DTC B160B-00. Inspection found visible water traces and copper corrosion inside the yellow connector beneath the steering column; insulation resistance between pins had dropped to 0.8Ω. Cleaned the connector with electrical contact cleaner, dried it thoroughly, then applied special conductive grease. After repair, insulation resistance recovered to 2.1Ω. Cleared the fault code; it has not returned. Recommend checking the vehicle's sealing, especially whether the drain holes are blocked.
BYD DTC AI AnalysisFrom Chinese market (translated)

Modified steering wheel caused abnormal circuit impedance

Owner fitted an aftermarket racing steering wheel and third-party airbag harness adapter. DTC B160B-00 appeared intermittently. Inspection found the modified harness used a resistor with too-low resistance (0.5Ω) to simulate the airbag load, causing the SRS ECU to detect insufficient resistance. Removed the modified components and refitted the original steering wheel and airbag assembly; the fault cleared. Advised the owner that any future modifications must use an equivalent resistor meeting BYD SRS system specifications (2.0±0.3Ω).
BYD DTC AI AnalysisFrom Chinese market (translated)

Worn steering column wiring harness caused short to ground

At 80,000 km, the airbag warning light illuminated intermittently, particularly on rough roads. Measuring during the fault showed the airbag circuit resistance to ground was 0.3Ω. Inspection found a sharp edge on the mounting bracket below the steering column. The edge had chafed through the airbag wiring harness insulation due to prolonged vibration, causing the copper conductors to short against the bracket. Repaired the damaged harness by re-wrapping with insulation tape and fitting protective sleeving, then rerouted the wiring to avoid contact with the metal edge. Completely resolved the fault.
BYD DTC AI AnalysisFrom Chinese market (translated)

Airbag module internal igniter short circuit

No collision history, but the airbag warning light suddenly illuminated with DTC B160B-00 that could not be cleared. Disconnected the airbag module connector and measured resistance between the module terminals: 0.6 Ω (normal: 2–3 Ω). Determined an internal igniter bridge wire short in the airbag. Replaced the driver airbag assembly, also replacing the mounting bolts and tightening them to 7.5 N·m. Performed coding and configuration with the special tool, and the system returned to normal.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.