B1773

On BYD new energy vehicles, DTC B1773 indicates a Cell Supervision Circuit (CSC) fault — Seal 6 EV

Safety System

On BYD new energy vehicles, DTC B1773 indicates a Cell Supervision Circuit (CSC) fault.

This represents a Battery Management System (BMS) subsystem communication or sampling abnormality, rather than the seat belt pretensioner issue in the original description (the latter belongs to the SRS system, indicating a possible mix-up in fault code definitions).

The CSC module continuously monitors key parameters within the power battery module, including individual cell voltage and temperature, and communicates with the main BMS via the internal CAN bus.

The BMS sets DTC B1773 when it fails to detect a response signal from a CSC within the specified timeframe (communication timeout), receives out-of-range data (e.g., a -40°C open-circuit temperature reading), or detects a CSC address conflict or duplication.

This fault activates the system safety protection strategy, limiting vehicle power output, disabling pure EV driving, or interrupting the charge/discharge process.

It severely compromises power battery thermal management and safety monitoring functions and requires immediate repair.

5
Cases Logged
BYD DTC AI Analysis

Song Pro DM battery information collection module communication fault (connector oxidation)

Symptoms: Dashboard displayed "Check Powertrain", EV mode unavailable, engine forced to start. Scanner read DTCs B1773 (Battery Information Collector fault) and P1A3400 (Battery Management System fault). Diagnosis: VDS showed CSC communication fault on string 5; removed battery pack detection harness and measured collector CAN line resistance >120 Ω (normal 60 Ω); inspection found corroded collector connector with backed-out terminal. Solution: Cleaned connector oxides, repaired backed-out terminal, and reconnected; resistance normalized. Cleared DTCs; EV mode restored. Check battery pack sealing to prevent moisture ingress.
Original source ↗
BYD DTC AI Analysis

Qin Pro DM temperature sampling abnormality (cold solder joint on chip)

Symptoms: Sudden power loss while driving; dashboard displayed "Powertrain Fault." Read DTC B1773 and multiple temperature sampling fault codes. Diagnosis: Live data showed Module 3 acquisition unit reporting all temperatures at -40°C (open circuit condition). Removed the battery pack and located the Module 3 CSC. NTC resistance measured normal, but the acquisition board had cold solder joints on the temperature sampling chip pins. Resolution: Replaced the Module 3 battery information collection board and reflashed the configuration parameters. Performed "Battery Information Collector Address Configuration" and "Capacity Learning." Fault cleared.
Original source ↗
BYD DTC AI Analysis

Tang DM charging system fault (internal short circuit in sampling unit)

Symptoms: Vehicle failed to charge (AC and DC both inoperative), instrument cluster displayed 'Charging System Fault'. Retrieved DTC B1773 and multiple BMS communication timeout faults. Diagnosis: OBC-to-BMS communication normal. Inspected the battery pack and found Group 8 CSC had lost communication with the master BMS. Measured the module supply voltage at 0V (normal 12V); the power fuse had blown. Replaced the fuse but it blew again immediately—internal short in the CSC. Resolution: Replaced the Group 8 CSC module and power fuse. Found impact damage to the battery pack underside had deformed the CSC housing and caused a short. Repaired the underbody shield to ensure sealing integrity.
Original source ↗
BYD DTC AI Analysis

e5 EV data collector address configuration error

Symptoms: Dashboard displayed powertrain fault warning with speed limit active; DTC B1773 would not clear. Diagnosis: Scan tool showed "Group 6 acquisition module address conflict" and "communication fault". Inspection found a previous battery module replacement at a non-authorised workshop. The replacement acquisition module had incorrect address coding; hardware functioned correctly but the wrong address prevented BMS recognition. Resolution: Used a dedicated scan tool to execute "battery acquisition module address learning", reconfiguring each acquisition module address to its physical location. Performed "system reset" and "insulation test"; fault cleared.
Original source ↗
BYD DTC AI Analysis

Song DM intermittent fault (poor harness contact)

Symptoms: Intermittent powertrain fault with EV mode unavailable when active; fault sometimes cleared after restart; frequency gradually increasing; historic DTC B1773 present. Diagnosis: Performed wiring harness wiggle test. Fault reoccurred when wiggling low-voltage wiring near the high-voltage battery pack. Inspection revealed broken retaining clip for the low-voltage loom inside the battery pack, and loose Module 2 cell monitoring connector with slightly burnt pins. Repair: Replaced wiring retaining clip and secured the loom. Cleaned and polished the Module 2 cell monitoring connector pins, applied conductive paste, reconnected the plug and secured it with cable ties. Road-tested 50 km; fault did not reoccur.
Original source ↗