DTC B2A2F09 indicates the air conditioning thermal management system detected abnormal refrigerant line pressure — Seal 6 EV
DTC B2A2F09 indicates the air conditioning thermal management system detected abnormal refrigerant line pressure.
Specifically, the high-pressure side pressure sensor reading falls outside the normal range (too high or too low).
This fault involves the electric compressor high-pressure line monitoring circuit.
The system triggers the fault when the pressure sensor detects a high-pressure side pressure > 3.2 MPa (overpressure protection) or < 0.2 MPa (underpressure protection).
This fault activates the air conditioning system safety protection mechanism and forces an electric compressor shutdown to prevent pipe rupture or compressor dry running, resulting in a loss of cooling.
In BYD new energy vehicles with highly integrated thermal management systems, this fault may also impair the battery cooling function, triggering vehicle thermal management power derating protection.
Thread damage to the high-pressure sensor caused air-conditioning failure on a BYD e5
BYD Qin A/C pressure sensor circuit open
BYD Qin low voltage supply abnormality triggered false pressure monitoring warning
BYD Song MAX: Poor condenser cooling caused high-pressure side over-pressure protection
Refrigerant leak caused low pressure on the low side of the BYD Qin EV