This fault code indicates the IPM (Intelligent Power Module) inside the air conditioning compressor controller detects an IGBT (Insulated Gate Bipolar Transistor) malfunction — Seal 6 EV
This fault code indicates the IPM (Intelligent Power Module) inside the air conditioning compressor controller detects an IGBT (Insulated Gate Bipolar Transistor) malfunction.
In the BYD thermal management system, the electric compressor operates on a high-voltage DC drive.
The IPM module inverts the high-voltage DC into three-phase AC to drive the compressor motor.
DTC B2AB2-49 indicates the controller detects a hardware-level fault in the power semiconductor device.
Possible causes include a triggered IGBT overcurrent protection, module overheating (junction temperature exceeding 150°C), an upper and lower bridge arm shoot-through short circuit, abnormal gate drive voltage, or activation of the IPM internal self-protection circuit (FO fault output).
This fault shuts down the compressor, affecting cabin cooling and battery pack thermal management (liquid cooling).
In extreme cases, it can trigger a protective disconnection of the high-voltage system.
Qin Pro EV AC Compressor IPM Thermal Breakdown Replacement Case
Qin EV300 false IPM fault caused by loose high voltage interlock connection
Qin PRO DM Compressor Controller Driver Board Repair Case
BYD Qin EV300: Refrigerant overcharge triggers IPM overvoltage protection