U025387

U025387 is a U-category network communication DTC — Seal U

Thermal Management System

U025387 is a U-category network communication DTC.

It indicates a CAN bus communication interruption between the Vehicle Control Unit (VCU) or thermal management controller and the Electric Air Conditioning Compressor Controller (ACCM).

This fault indicates the main control unit failed to receive valid messages (such as status, speed, and fault data) from the compressor controller within the predetermined cycle (typically 100ms-500ms).

This represents a control link communication loss rather than a mechanical failure of the compressor itself.

The fault completely disables the air conditioning system (no cooling/heating).

This failure subsequently triggers battery thermal management degradation (limiting fast charge power and affecting battery life) and causes insufficient motor cooling (triggering high-temperature protection and power reduction).

Severe cases restrict EV functions or prevent the vehicle from starting.

5
Cases Logged
BYD DTC AI Analysis

Qin PLUS DM-i won't start after high-temperature exposure (wiring harness connector pin backed out)

Symptoms: After high-temperature exposure, the vehicle failed to start and the instrument cluster displayed all warning lights, logging 12 communication faults including U025387, U014087, and U029887. Diagnosis: VDS scanning revealed the VCU lost communication with multiple modules. Energy Network CAN resistance measured 238.5Ω when hot (abnormal), returning to normal 67.1Ω after cooling. Inspection found loose pins backing out of the front compartment harness connector; thermal expansion caused poor contact. Solution: Repaired the front compartment harness connector and secured the pins. No recurrence after two weeks of monitoring.
Original source ↗
BYD DTC AI Analysis

Tang DM EV Function Limited (Module Version Mismatch)

Symptoms: EV function limited, pure electric mode unavailable, air conditioning inoperative. Diagnosis: VDS scan showed the system was at latest version, but further inspection revealed the A/C compressor controller failed to recognize integrated body controller B2, setting DTC U025387 (Lost Communication With A/C Compressor). Power and ground at the compressor low-voltage connector measured normal; insulation resistance normal. Resolution: Software version mismatch confirmed. Performed software upgrade and matching on the A/C compressor controller and integrated body controller B2. Communication restored after refresh; EV functions returned to normal.
Original source ↗
BYD DTC AI Analysis

Qin Pro DM A/C compressor insulation failure caused communication interruption

Symptoms: Instrument cluster displayed 'EV Function Limited' and the air conditioning compressor would not start. Diagnosis: Retrieved DTC U025387. Checked compressor low-voltage harness supply – normal. Used a megohmmeter to measure high-voltage insulation resistance from compressor to ground; reading was only 0.5 MΩ (far below the 2 MΩ standard), indicating internal leakage. Further disassembly revealed deteriorated scroll plate seals. Refrigerant leakage degraded motor winding insulation, forcing the controller into protective sleep mode. Resolution: Replaced the electric compressor assembly and fitted upgraded scroll plate seals. Refilled POE refrigerant oil. Fault resolved.
Original source ↗
BYD DTC AI Analysis

Qin EV: AC Suddenly Failed While Driving (CAN Network Resistance Drift)

Symptoms: Air conditioning suddenly stopped working while driving. Instrument cluster displayed thermal management fault; DTC U025387. Diagnosis: Static measurement showed CAN resistance normal (60Ω). When simulating driving vibration and temperature changes, powertrain CAN resistance fluctuated between 60Ω–120Ω. Found internal break in shielded twisted pair between right domain controller connector E and compressor (intermittent open), causing poor contact under vibration. Solution: Replaced CAN communication harness from front compartment to compressor and repaired shielding. Fault resolved.
BYD DTC AI Analysis

Qin PLUS EV communication fault after compressor replacement (software not configured)

Symptoms: Electric compressor replaced during accident repair. AC not cooling; DTC U025387 (Loss of Communication) logged. Diagnosis: New compressor power, ground, and CAN line voltage normal, but VDS cannot recognize the compressor controller. Replacement unit is a blank part or from a different batch, missing software configuration and VIN matching. Solution: Performed the 'Replace Electric Compressor' service routine using VDS, wrote vehicle configuration parameters, and ran communication matching and calibration between the compressor and VCU. After flashing, communication established and AC returned to normal.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.