B178D

DTC B178D indicates the front passenger second-stage frontal airbag (Passenger Frontal Airbag Stage 2) ignition circuit is disconnected or has abnormal resistance — Atto 3

Safety System

DTC B178D indicates the front passenger second-stage frontal airbag (Passenger Frontal Airbag Stage 2) ignition circuit is disconnected or has abnormal resistance.

In BYD e-Platform 3.0 models featuring a distributed electronic architecture (e.g., Dolphin, Seal, Yuan PLUS), this DTC may also indicate a communication interruption between the Right Body Domain Controller (R-DCU) and the SRS module, or a sub-node fault.

The airbag utilizes a dual-stage ignition design to deploy in stages based on collision severity (stage 1 low-pressure deployment; stage 2 high-pressure supplementary deployment).

This fault prevents the front passenger airbag from executing the second-stage deployment during a collision or causes complete airbag failure, severely compromising occupant protection.

Inspect the airbag module wiring harness, connectors, clock spring (if applicable), and domain controller communication status.

3
Cases Logged
BYD DTC AI Analysis

BYD Song PLUS DM-i Blind Spot Monitoring Restricted (Right Domain Controller Fault)

Symptom description: Dashboard displayed "Blind Spot Function Limited" warning; blind spot monitoring switch not shown on centre touchscreen; VDS failed to detect right blind spot monitoring module. Diagnostic process: 1. Scanned with VDS; right blind spot monitoring module had no communication. 2. Inspected right body controller (right domain) and confirmed the module communicates via this unit. 3. Checked power supply, ground and CAN wiring to right domain controller; found internal fault in the controller was preventing the blind spot module from working. 4. Cross-check: Swapped right body controller and fault disappeared. Resolution: Replaced right body domain controller (right domain), reprogrammed and cleared the fault.
Original source ↗
BYD DTC AI Analysis

BYD Song Plus DM-i Multiple Switch Group Failure (Right Domain Communication Fault)

Symptoms: Light switch would not turn on lights, wiper switch would not control wipers, and all steering wheel buttons did not respond. Instrument cluster displayed "Lane Departure Function Limited" and "Lane Keeping Function Limited". Diagnosis: 1. VDS scan found communication errors between left and right domain controllers. 2. Multiple switch signals route through the body domain controller; identified as inter-domain controller communication failure. 3. Checked power supply and network wiring to domain controllers; measured abnormal voltage on CAN lines. 4. Confirmed right body domain controller had corrupted internal software, blocking switch signal transmission. Resolution: Updated software on right body domain controller. Fault cleared after update. Some vehicles require replacement of the right domain controller.
Original source ↗
BYD DTC AI Analysis

BYD e2 AC not cooling (Integrated Body Controller/Right Domain fault)

Symptom: AC stops cooling after running for a while. No cold air even with temperature set to minimum. Diagnosis: 1. VDS scan showed Integrated Body Controller logged fault code "AC line in high pressure or low pressure state". 2. AC pressure sensor and wiring checked normal. 3. Found Integrated Body Controller (AC controller integrated in right domain) outputting abnormal control signal to electronic expansion valve. 4. Data stream showed abnormal duty cycle from right domain controller driving expansion valve. Repair: Replaced Integrated Body Controller (right domain). Recalibrated AC system. Fault resolved.
Original source ↗
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.