This DTC indicates a short to ground in the refrigerant temperature sensor signal circuit at the inlet or outlet of the battery cooling system plate heat exchanger (Chiller/battery cooler), or an internal short circuit within the sensor — Atto 3
This DTC indicates a short to ground in the refrigerant temperature sensor signal circuit at the inlet or outlet of the battery cooling system plate heat exchanger (Chiller/battery cooler), or an internal short circuit within the sensor.
This NTC thermistor outputs a 0.5-4.5 V analog voltage signal to the Thermal Management System (TMS) controller or A/C controller to monitor the temperature of the refrigerant flowing through the plate heat exchanger in real time.
This parameter is critical for precisely controlling battery cooling intensity and preventing battery overcooling or overheating.
The controller logs a short circuit fault when the signal voltage remains below 0.1 V (near 0 V) for a specified duration (typically 2-5 seconds).
The thermal management system then enters fail-safe mode, immediately cutting off refrigerant flow to the battery cooling circuit and limiting battery charge and discharge power.
In severe cases, the system triggers a vehicle-level 'Thermal Management System Fault' warning and prohibits high-voltage power-on.
This prevents continued operation with unknown refrigerant temperatures, which could cause battery thermal runaway or compressor liquid slugging damage.
Underbody scrape wore through wiring harness causing intermittent short circuit
Internal short in aging sensor caused battery cooling failure
Connector water ingress after wading caused corrosion and short circuit
False alarm from wiring harness installed incorrectly after accident repair