This fault code indicates abnormal damper actuator position control within the air conditioning thermal management system — Atto 3
This fault code indicates abnormal damper actuator position control within the air conditioning thermal management system.
Specifically, the recirculation door or blend door servo motor fails to reach the target position within the set time (typically 3-5 seconds), or the actual position feedback from the position sensor (generally a Hall effect sensor) deviates from the controller command by more than the threshold (typically >5%).
According to the control logic, the AC controller outputs a PWM signal to drive the motor while monitoring the sensor feedback voltage (0.5-4.5V range).
The controller triggers this code upon detecting a motor stall, step loss, sensor signal interruption, or abnormal voltage.
This fault disables fresh air/recirculation switching, delays cabin temperature adjustment, and causes abnormal demist mode operation.
In extreme cases, it affects battery pack cooling efficiency on vehicles utilizing an A/C refrigerant battery cooling architecture.
Recirculation flap gearset fracture caused fresh air/recirculation mode failure on Song MAX
Oxidized wiring harness connector caused signal drift on the Qin EV
Qin PRO DM: Evaporator icing jamming the air door
Replaced actuator without initializing it, causing the fault to persist.
Controller software defect causing false low-temperature warning