This DTC indicates the IPB (Intelligent Power Brake) electro-hydraulic control module detects the brake booster motor drive circuit supply voltage exceeds the calibrated threshold (typically >16V) — Atto 3
This DTC indicates the IPB (Intelligent Power Brake) electro-hydraulic control module detects the brake booster motor drive circuit supply voltage exceeds the calibrated threshold (typically >16V).
In BYD DMi models, the 12V low-voltage system powers the IPB, which uses motor direct-drive brake assist (without a vacuum booster).
Faults in the DC-DC converter, generator, or IPB internal power management circuit causing voltage increases trigger this DTC.
Continuous overvoltage can overheat and damage the IPB internal MOSFETs or motor driver chip.
This triggers system protection mode, resulting in a hard brake pedal, reduced brake assist, or restricted ABS/ESC functions.
Severe cases force the vehicle into limp mode.
Song PLUS DM-i DC-DC Output Overvoltage Causing C059000
Faulty IPB internal sampling circuit falsely reporting overvoltage
Wiring harness wear caused stray voltage to enter the IPB power supply.
Generator regulator failure caused hybrid mode overvoltage