The internal voltage monitoring circuit in the Air Conditioning Control Unit (ACU) or Integrated Thermal Management System (ITMS) controller triggers DTC B2A0716 — Atto 8
The internal voltage monitoring circuit in the Air Conditioning Control Unit (ACU) or Integrated Thermal Management System (ITMS) controller triggers DTC B2A0716.
This indicates the supply voltage in power circuit 161 (typically the constant B+ or IG ignition supply for the air conditioning module) falls below the 9V operating threshold.
This fault signifies a low-voltage supply abnormality in the thermal management system.
Upon detecting insufficient operating voltage, the controller logs the fault and may enter a degraded protection mode.
This mode limits the electric compressor speed, shuts off the PTC heater, or halts electronic expansion valve operation, reducing or disabling air conditioning cooling and heating functions.
In extreme cases, this condition affects the traction battery cooling circuit and triggers overheat protection.
BYD Song MAX: Intermittent A/C cooling failure with DTC B2A0716
BYD Tang DM on-board charger DC-side low voltage fault (P157216)
BYD Qin Early Charging Termination (Abnormal Voltage Detection Reference)