B2A4B14

This DTC indicates a fault in the drive circuit of the HVAC Recirculation Air Door Actuator motor — Atto 8

Thermal Management System

This DTC indicates a fault in the drive circuit of the HVAC Recirculation Air Door Actuator motor.

Specifically, a "short to ground" indicates insulation failure between the motor supply line (typically the PWM control line or power line) and the vehicle body ground (GND), causing abnormal current leakage.

An "open circuit" indicates a broken internal motor coil, a loose connector, or a severed wiring harness.

This motor switches the HVAC air door between fresh air and recirculation modes.

A fault prevents mode switching or causes the door to stick in a fixed position, reducing cabin temperature control efficiency.

In extreme cases, this reduces battery thermal management performance (e.g., preventing effective heat dissipation via fresh air mode).

Therefore, the system classifies this as a severe fault.

3
Cases Logged
BYD DTC AI Analysis

Song MAX recirculation door jammed, motor burned out

A 2018 BYD Song MAX DM with 60,000 km displayed "Air Conditioning System Fault" on the dashboard. Found DTC B2A4B14. Disassembly revealed mud ingress at the recirculation door actuator connector and the door shaft jammed with accumulated leaves and dust. The motor continuously attempted to drive while stalled, overheating and burning out the internal coil. Measured resistance: 0.5Ω (short to ground). Solution: Cleaned the door mechanism and foreign objects from the HVAC unit, lubricated the shaft, replaced the recirculation door actuator, and cleaned and waterproofed the wiring harness connector. Fault resolved.
BYD DTC AI Analysis

Qin Pro EV HVAC unit wiring harness chafed, shorted to ground

2019 BYD Qin Pro EV. Intermittent B2A4B14 DTC. When the fault occurred, the recirculation mode would not switch. Inspection revealed the fault occurred on rough roads. Removed the passenger side dashboard and found the recirculation flap actuator power supply wire (pink) had chafed against a metal body bracket where it passes through the firewall. Damaged insulation caused an intermittent short to earth. Measured resistance from the wire to earth with a multimeter; resistance fluctuated between 0–10 ohms when moving the harness. Repair: Cut out the damaged section, soldered in an extension, and insulated with double-layer heat shrink tubing. Re-secured the harness routing and added a rubber grommet to prevent chafing. Fault has not reoccurred.
BYD DTC AI Analysis

Qin EV300 Actuator Internal Open Circuit Fault

2017 BYD Qin EV300. Air conditioning recirculation mode inoperative, system forced to fresh air mode with DTC B2A4B14 stored. Scan tool live data showed 'Invalid' for flap position. Measured motor coil resistance at the recirculation flap actuator connector: open circuit (infinite resistance). Disassembled the actuator: gearset intact, but motor brushes severely worn causing open circuit. This model uses a sealed, non-serviceable actuator. Replaced the air conditioning recirculation flap actuator assembly (part number similar to BG-8112600). Performed flap calibration after replacement. Recirculation and fresh air functions returned to normal.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.