B110D09

DTC B110D09 indicates a failure of the internal photoelectric receiving module in the PM2 — Qin Plus

Thermal Management System

DTC B110D09 indicates a failure of the internal photoelectric receiving module in the PM2.5 rapid detector (laser particulate sensor).

The sensor operates on the laser scattering principle: a laser diode emits a beam to illuminate an air sample.

Suspended particulate matter produces scattered light.

The photoelectric receiving module (typically a high-sensitivity photodiode or photomultiplier tube) captures this light and converts it into an electrical signal.

The signal processing circuit then calculates the PM2.5 concentration.

DTC B110D09 specifically refers to a fault in the module receiving the scattered light.

Possible causes include photoelectric component aging or burnout, a signal amplification circuit fault, A/D conversion module damage, or an internal open circuit.

This fault prevents the Green Air Purification System from obtaining accurate air quality data, disabling the automatic air purification mode and the A/C automatic fresh air/recirculation switching function.

Although this fault typically does not affect the powertrain or driving safety, it disables the thermal management system's environmental adaptive control strategy.

The system classifies this fault as severe because abnormal communication between the sensor and the A/C control module can trigger cascading faults.

5
Cases Logged
BYD DTC AI Analysis

Atto 3 PM2.5 sensor photoelectric receiver module damaged

Instrument cluster displayed an air quality detection malfunction, and the air purification function failed in automatic AC mode. Scanned the AC system with a diagnostic tool and retrieved DTC B110D09 (PM2.5 detector photoelectric receiver module failure). Checked PM2.5 sensor wiring: connections normal, supply voltage 5V (within spec), no short circuit on signal line. Determined internal photoelectric receiver tube aged and failed from long-term use. Replaced PM2.5 air quality sensor assembly, cleared DTCs, and performed sensor initialization. System returned to normal; PM2.5 readings update correctly with ambient changes.
BYD DTC AI Analysis

Qin Pro EV Green Net system intermittent fault (B110D09)

Owner reported cabin air quality display intermittently disappearing and the Green Air system working inconsistently, sometimes recovering after an ignition cycle. Scan tool retrieved intermittent DTC B110D09. Found the PM2.5 sensor behind the glovebox; its connector was not fully seated, causing intermittent contact when the vehicle vibrated. Reseated the connector and secured it with electrical tape. Sensor optical window also had slight dust contamination; cleaned it and the fault resolved. Live data now shows stable readings.
BYD DTC AI Analysis

Song Pro DM-i optical receiver module failure due to optical path contamination

After long-term use in a dusty environment (near construction sites), the instrument cluster reported an air quality system fault. Read DTC B110D09. Disassembly revealed heavy dust accumulation inside the PM2.5 sensor optical cavity. Dust on the photoelectric receiver surface prevented light signal reception. Since dust had entered the internal optical components, cleaning only the exterior could not restore function. Replaced the PM2.5 sensor assembly and added filter cotton at the air intake to prevent future contamination. Fault resolved.
BYD DTC AI Analysis

Han EV dual-zone air quality detection failure - passenger side

The Han EV has a dual-zone PM2.5 monitoring system. The owner noticed the passenger side air quality display constantly showed '--' or a fixed value, while the driver's side worked normally. The scan tool read DTC B110D09, pointing to the passenger side PM2.5 sensor. Power supply and ground to the sensor were normal, but the signal output voltage was 0V (normal analog signal: 0.5-4.5V). This indicated an open circuit in the passenger side sensor's internal photoelectric receiver module. After replacing the sensor, we performed a dual-zone sensor calibration using the scan tool. Both sides now display correctly.
BYD DTC AI Analysis

Qin EV300: Chafed PM2.5 sensor wiring loom caused photoelectric receiver module failure

The vehicle intermittently displayed an air quality system fault warning, with intermittent DTC B110D09. Inspection found the sensor wiring harness insulation had worn through at the dashboard frame mounting point due to long-term friction, leaving the copper wires partially exposed. When the vehicle hit bumps, the exposed wires shorted to the metal frame, causing the photoelectric receiver module supply voltage to drop momentarily and trigger the fault. We repaired the damaged harness (re-insulated and wrapped), rerouted the harness to avoid contact with sharp edges, and replaced the PM2.5 sensor, as voltage fluctuations may have damaged it. The fault was completely resolved.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.