B162A

DTC B162A indicates the airbag control module (SRS ECU) detects a driver airbag ignition circuit resistance of 0 Ω or below the 1 — Qin Plus

Safety System

DTC B162A indicates the airbag control module (SRS ECU) detects a driver airbag ignition circuit resistance of 0 Ω or below the 1.5 Ω threshold, identifying a short to ground or a shorted circuit.

In the BYD SRS system, this circuit includes the clock spring, spiral cable, connectors, and airbag inflator.

A 0 Ω resistance means current may flow directly to ground.

The ECU disables the airbag to prevent accidental deployment and illuminates the instrument cluster airbag warning lamp.

This fault constitutes a hard short circuit, unlike an open circuit (infinite resistance).

However, broken wires inside the clock spring contacting each other or grounding can also cause an intermittent short circuit.

This fault prevents the driver front airbag from deploying during a collision, severely compromising passive safety.

5
Cases Logged
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD Qin Pro DM clock spring internal short circuit

Symptoms: Dashboard airbag warning light constantly on; no accident history. Diagnosis: Read DTC B162A (driver airbag circuit resistance too low). Clock spring resistance fluctuated between 0.5–1.2 Ω (normal: 2–3 Ω). Disassembly found worn insulation on the internal flat cable, causing a local short circuit. Solution: Replaced the clock spring with genuine part KZ-541XXX, re-centred it during installation, then cleared fault codes. The system returned to normal.
Original source ↗
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD Song Pro airbag connector short circuit due to water ingress

Symptoms: Airbag warning light comes on after rain or car wash, and occasionally on rough roads. Diagnosis: B162A intermittent fault. Inspected the yellow connector under the steering wheel; the seal was missing and green copper corrosion was inside. Resistance measured between pins indicated occasional short circuits. Solution: Disconnected the battery, cleaned the connector with electronic contact cleaner, blew it dry, applied conductive grease, and replaced the locking clip with a new one to ensure a proper seal. Fault resolved.
Original source ↗
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD Han EV combination switch assembly fault

Symptoms: Airbag warning light flashes when turning the steering wheel; multifunction buttons not working. Diagnosis: Live data showed the driver airbag circuit resistance jumping between 0Ω and 5Ω as the steering wheel turned. This indicated an internal cable break in the clock spring (integrated in the combination switch) that caused a short to ground. Solution: Replaced the combination switch assembly (includes clock spring, HA-341XXX). Calibrated the steering angle sensor and wrote the airbag configuration using a diagnostic tool.
Original source ↗
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD Tang DM-i short circuit after accident repair

Symptom: After a front collision and airbag replacement, the fault light stayed on. Diagnosis: Pulled DTC B162A. New airbag resistance measured normal, but the harness side showed 0 Ω to ground. Found the clockspring had been pinched during the impact, causing an internal short. An SRS ECU connector pin had also retracted and was contacting the housing. Solution: Replaced the clockspring, repaired the connector pin, performed the airbag reconfiguration procedure, and cleared the codes. System returned to normal.
Original source ↗
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD e5 taxi wiring harness chafed and shorted

Symptoms: High-mileage taxi (250,000 km) with airbag warning light on and horn not working. Diagnosis: DTCs B162A and B162B both present. Inspection found the wiring harness under the clock spring worn through from prolonged full-lock steering. Damaged insulation caused wires to contact steering column metal and short to ground. Repair: Replaced clock spring, fitted heat-resistant protective sleeving to harness at steering column wear point, and rerouted harness to prevent excessive flexing.
Original source ↗
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.