B168500

DTC B168500 indicates an invalid configuration fault in A/C System Circuit 1 (specifically the electric compressor drive circuit) — Qin Plus

Safety System

DTC B168500 indicates an invalid configuration fault in A/C System Circuit 1 (specifically the electric compressor drive circuit).

On BYD Qin PRO models, 'Circuit 1' typically refers to the electric A/C compressor high-voltage drive and LIN communication circuits. 'Invalid configuration' indicates mismatched communication parameters between the HVAC ECU and the compressor control unit, an unconfigured LIN address, or abnormal circuit topology recognition.

This fault completely disables the A/C cooling function and may limit vehicle power output.

Although some sources classify this as an SRS fault, the BYD fault code structure (B16xxxx) categorizes it under the body HVAC system, with no direct relation to the airbags.

4
Cases Logged
BYD DTC AI Analysis

Qin Pro DM: B168500 caused by missing coding after compressor replacement

A 2019 Qin PRO DM received a replacement electric compressor due to abnormal noise. After installation, the A/C did not cool. No warning lights appeared on the instrument panel, but the HVAC system stored DTC B168500. Technicians found the new compressor had not been configured as a LIN node. Using the VDS2000 diagnostic tool, they entered 'Special Functions' > 'Replace Electric Compressor', input the part number from the new compressor label (e.g., BC28-XXXX), and executed the coding. The fault code cleared automatically and the air conditioning returned to normal.
BYD DTC AI Analysis

Loose LIN connector caused intermittent B168500

2018 Qin Pro EV owner reported the air conditioning intermittently cut out while driving, resuming after a restart. Scan tool detected stored DTC B168500. Found the low-voltage connector (4-pin) for the front electric compressor had a broken internal locking tab, causing poor contact on the LIN line (typically pin 3). Repaired the harness connector, replaced the connector housing, and secured the harness against vibration. Fault has not recurred.
BYD DTC AI Analysis

Internal fault in the HVAC controller caused a circuit configuration error

After wading through water, a 2019 Qin Pro petrol variant lost all air conditioning. DTC B168500 stored and could not be cleared. Inspection of the compressor and wiring showed normal operation, but the LIN bus voltage measured 0 V continuously. Disconnecting the compressor connector did not restore normal LIN voltage, indicating a failed LIN transceiver inside the AC controller. Replaced the HVAC controller assembly, performed online configuration and temperature motor self-learning, and resolved the fault.
BYD DTC AI Analysis

Invalid configuration due to software version mismatch

A 2018 Qin PRO DM logged DTC B168500 after a system update at the dealership. A TSB search revealed a compatibility issue between the early HVAC software and new compressor control logic on this model. The tech downloaded a specific patch from the BYD after-sales system and downgraded the AC controller software to the stable version (or upgraded to the corrected release). The DTC cleared and the AC now works normally.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.