This DTC indicates a phase loss in the internal three-phase permanent magnet synchronous motor of the electric A/C compressor (E-Compressor) — Qin Plus
This DTC indicates a phase loss in the internal three-phase permanent magnet synchronous motor of the electric A/C compressor (E-Compressor).
When the compressor controller (inverter) supplies power to the motor U/V/W three-phase windings, it detects a loss of at least one phase current or a voltage drop exceeding the threshold.
Open windings, open high-voltage harnesses, or damaged IGBT power modules typically cause this condition.
This fault prevents the compressor from generating effective torque and forces it to stop, which disables the A/C cooling and heating functions and triggers the thermal management system derating protection.
In vehicles like the BYD Qin EV, battery cooling relies on the A/C refrigerant circuit; therefore, this fault may indirectly raise the battery pack temperature and limit charge and discharge power.
Burnt high-voltage plug on Qin EV compressor causing intermittent phase loss
Damaged electric compressor IGBT module triggered phase loss protection
Refrigerant leak caused compressor overheating and phase loss
High-voltage distribution box relay contacts burned