DTC B2AB249 indicates a fault in the IGBT (Insulated Gate Bipolar Transistor) power device or drive circuit inside the electric air conditioning compressor drive module (IPM, Intelligent Power Module) — Seal 6 EV
DTC B2AB249 indicates a fault in the IGBT (Insulated Gate Bipolar Transistor) power device or drive circuit inside the electric air conditioning compressor drive module (IPM, Intelligent Power Module).
In models such as the BYD Qin EV, high-voltage DC drives the electric compressor.
The IPM converts this high-voltage DC power into three-phase AC power to drive the compressor motor.
IGBT overcurrent, overtemperature, overvoltage, or an internal module short circuit typically triggers this fault, initiating compressor shutdown protection.
This affects air conditioning cooling/heating functions and battery thermal management capabilities.
This is a hardware-level fault; in most cases, a power reset cannot permanently clear it.
Qin EV AC intermittent cooling failure, IPM overtemperature protection
After replacing the compressor, the IPM fault kept recurring due to a backed-out high-voltage interlock pin.
IGBT module breakdown caused complete air conditioning failure
IPM fault triggered after fast charging due to abnormal PDU output voltage.
Compressor mechanical seizure triggered IGBT overcurrent protection.