DTC B2AB64B indicates the electric A/C compressor internal temperature monitoring point detects an abnormally high temperature or an abnormal temperature signal — Seal 6 EV
DTC B2AB64B indicates the electric A/C compressor internal temperature monitoring point detects an abnormally high temperature or an abnormal temperature signal.
On 2019 BYD Qin EV models, this fault typically indicates the electric scroll compressor (BYD in-house or third-party supplied) internal motor winding temperature, power module (IPM) temperature, or compressor housing temperature exceeds the normal operating range (typical threshold: 110–130°C).
When this fault occurs, the compressor controller enters protection mode.
It limits compressor speed or stops operation to prevent insulation damage or mechanical seizure.
Because the Qin EV uses the A/C system for battery thermal management (the battery chiller integrates into the A/C circuit), this fault causes loss of cabin cooling and can reduce traction battery cooling capacity, subsequently triggering battery thermal management power derating protection.
Minor refrigerant leak triggered compressor thermal protection.
Loose connection in compressor temperature sensor wiring harness causing false alarms
Seized compressor bearing caused high temperature
High ambient temperature and high battery cooling load caused overheating