DTC B122111 indicates a short to ground or abnormally low signal circuit impedance in the air conditioning/thermal management system RHS Fin Temperature Sensor — Seal U
DTC B122111 indicates a short to ground or abnormally low signal circuit impedance in the air conditioning/thermal management system RHS Fin Temperature Sensor.
This sensor is typically an NTC (negative temperature coefficient) thermistor with a normal operating voltage range of 0.5-4.5V.
The ECU triggers this fault when the signal voltage remains below 0.1V (short-circuit threshold) for longer than a set time (typically 2-5 seconds).
In Qin EV/Qin Pro DM models, this sensor mounts on the right-hand fin of the PTC heater assembly or at the heater core outlet to monitor the heater operating temperature and prevent overheating.
A short circuit prevents the thermal management ECU from obtaining accurate temperature data.
The ECU then triggers a protection mechanism that shuts down the PTC heater and restricts the air conditioning heating function.
In extreme cases, this condition opens the high-voltage interlock and forces the vehicle into limp mode.
Qin Pro DM heater failure after wading
Qin EV300 PTC heater internal short circuit
Wiring harness chafing caused an intermittent short circuit.
False positive fault - ECU software issue