This DTC indicates the Battery Thermal Management Electric Water Pump supply voltage falls below the system normal operating threshold (typically below 9V or 10 — Seal U
This DTC indicates the Battery Thermal Management Electric Water Pump supply voltage falls below the system normal operating threshold (typically below 9V or 10.5V, depending on vehicle calibration).
In the BYD Qin EV thermal management system, this water pump circulates coolant between the battery pack and the heat exchanger to maintain cell temperature within the optimal 15–35°C operating range.
During an undervoltage fault, the pump may experience an abnormal speed drop, stop intermittently, or fail completely, reducing battery cooling and heating efficiency.
Prolonged operation with this fault can trigger the BMS power limit protection strategy (reduced-power driving) and, in extreme cases, pose a risk of battery thermal runaway.
The air conditioning controller (or thermal management controller) triggers this fault upon detecting an abnormal PWM feedback signal from the water pump or an abnormal power supply voltage.
Oxidised water pump connector causing intermittent undervoltage on Qin EV
Aging 12V battery caused cascading undervoltage failure in water pump
Internal short circuit in the water pump burned the fuse holder.