This fault code indicates the supply voltage or feedback voltage of the heat pipe electric water pump in the Battery Thermal Management System (BTMS) exceeds the calibrated threshold (typically exceeding 16V in the low-voltage system, or abnormal high-voltage sampling) — Seal U
This fault code indicates the supply voltage or feedback voltage of the heat pipe electric water pump in the Battery Thermal Management System (BTMS) exceeds the calibrated threshold (typically exceeding 16V in the low-voltage system, or abnormal high-voltage sampling).
In models like the BYD Qin EV, the VCU or Thermal Management Controller (TMS) drives this water pump via a PWM signal (100-900Hz).
Upon fault trigger, the system records freeze-frame voltage data.
Overvoltage may cause water pump drive MOSFET breakdown and motor winding insulation aging, triggering battery thermal management derating protection (limiting charge and discharge power).
Prolonged overvoltage may cause insufficient battery pack heat dissipation, but typically does not affect driving safety before triggering overheat protection.
Differentiate between genuine overvoltage (power supply system fault) and false overvoltage (sampling circuit or sensor fault).
Excessive DC-DC converter output voltage caused water pump overvoltage alarm.
Water pump connector oxidation caused abnormal contact resistance
Thermal management controller software false overvoltage alarm
Battery coolant pump internally short-circuited and burned out
Abnormal interference of the high-voltage interlock loop with low-voltage signals