This DTC indicates the airbag control unit (SRS ECU) detects a short to vehicle power (12V/B+) in the front passenger airbag Stage 2 inflator circuit — Seal U
This DTC indicates the airbag control unit (SRS ECU) detects a short to vehicle power (12V/B+) in the front passenger airbag Stage 2 inflator circuit.
Dual-stage airbags feature two independent inflators for different crash severities: Stage 1 provides cushioning in minor collisions, and Stage 2 provides additional protection in severe collisions.
A short to power indicates an abnormal electrical connection between the inflator wiring and the battery positive terminal.
This fault causes the SRS system to enter fail-safe mode, illuminates the airbag warning light, and disables the front passenger airbag Stage 2 deployment function.
In extreme cases, it causes unintended airbag deployment or prevents normal deployment during a collision, creating a severe safety risk.
Clock spring internal short caused intermittent fault
Dashboard modification pinched wiring harness, causing short circuit
Connector corrosion and short circuit after water ingress
SRS ECU internal driver chip failure
Internal squib short circuit in airbag module