DTC B2A0813 indicates an open circuit in the air conditioning system evaporator outlet refrigerant temperature sensor (PT sensor) circuit — Seal U
DTC B2A0813 indicates an open circuit in the air conditioning system evaporator outlet refrigerant temperature sensor (PT sensor) circuit.
This sensor uses an NTC thermistor to monitor the evaporator outlet refrigerant temperature in real time (typical range -40°C to +85°C).
It provides critical temperature feedback to the HVAC ECU to precisely control the electronic expansion valve opening, compressor speed, and blower airflow, preventing evaporator surface icing and optimizing cooling efficiency.
The ECU logs an open circuit fault when it detects the sensor signal voltage continuously exceeding the threshold (typically above 4.95V, indicating an open circuit) for longer than a set time (e.g., 2 seconds).
This fault triggers the air conditioning system fail-safe mode, forcibly limiting compressor operation or completely stopping cooling, and may illuminate the relevant thermal management warning lamp.
Continuing to drive the vehicle may cause abnormal battery pack or motor heat dissipation, making this a severe fault.
Qin EV300 evaporator temperature sensor wiring harness chafed, open circuit
Intermittent fault on new Yuan Plus from loose sensor connector
Tang DM sensor pins corroded open after water wading
Aftermarket modification on Song Pro EV caused wiring harness to break under tension
Han EV heat pump system sensor failure due to aging