B178B-00

This fault code indicates that the resistance of the second stage (Level 2, typically the full-power deployment mode for severe collisions) inflator squib in the front passenger airbag dual-stage deployment circuit falls below the safety threshold set by the SRS ECU (generally below 1 — Atto 3

Safety System

This fault code indicates that the resistance of the second stage (Level 2, typically the full-power deployment mode for severe collisions) inflator squib in the front passenger airbag dual-stage deployment circuit falls below the safety threshold set by the SRS ECU (generally below 1.5 Ω).

In BYD dual-stage airbag systems, the first and second stages correspond to different collision severities.

The system achieves staged deployment by controlling different firing circuits.

Low resistance indicates the ECU detects an abnormal drop in circuit impedance and identifies a short circuit fault.

The system enters a safety protection state and disables the airbag to prevent accidental deployment, rendering the airbag inoperative during a collision.

This fault directly affects collision safety protection and requires immediate repair.

4
Cases Logged
BYD DTC AI Analysis

BYD Qin EV300: Connector came loose after dashboard removal and refit, causing B178B-00

A 2017 Qin EV300 showed a constant airbag warning light after the dealership replaced the air conditioning evaporator. VDS retrieved DTC B178B-00. The technician found the passenger airbag harness connector (yellow plug) had not fully seated during dashboard removal and installation, and terminal oxidation caused reduced contact resistance. The technician reseated the connector, treated the terminals with electronic cleaner, and cleared the DTC. The system self-test passed and the fault resolved.
Original source ↗
BYD DTC AI Analysis

BYD Qin 100 airbag module internal short after collision repair

A 2017 Qin 100 sustained a minor frontal impact. External damage was slight and the airbags did not deploy, but the instrument cluster displayed an airbag fault after repairs. Diagnosis revealed DTC B178B-00; measured resistance on the passenger airbag second stage circuit was only 0.6Ω (normal 2.0–3.0Ω). Disassembly revealed the airbag inflator internal bridge wire had deformed from the impact, causing a short to the housing. Replaced the OEM passenger front airbag assembly (part number: ...verify against vehicle specification) and completed system calibration. Fault resolved.
BYD DTC AI Analysis

Qin EV450 intermittent fault from connector oxidation after water wading

A 2018 Qin EV450 developed an intermittent airbag warning light after driving through deep water in heavy rain; the light sometimes cleared after a restart. A VDS scan retrieved historic fault code B178B-00. Inspection revealed damage to the passenger-side floor harness grommet, letting moisture into the airbag harness connector. This reduced insulation resistance between terminals and created a micro-short. Fix: thoroughly cleaned the connector terminals, dried the harness interior with a heat gun, applied waterproof insulating silicone grease to the connector, and installed a waterproof protective sleeve. The fault has not returned.
BYD DTC AI Analysis

Aftermarket modification pinches wiring harness, causing short on Qin 80

A 2017 Qin 80 owner self-installed a Head-Up Display (HUD), routing the wiring through a dashboard gap and accidentally pinching the passenger airbag harness. After some time, the airbag warning light illuminated with DTC B178B-00. Inspection found the harness insulation chafed against the dashboard metal bracket, causing the second-stage trigger wire to short to ground. The repair involved fixing the damaged harness (replacing the entire section or wrapping locally), repositioning the HUD wiring to avoid the airbag harness, and clearing the fault codes. The system then returned to normal.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.