DTC B2AB6-4B indicates the Electric A/C Compressor internal temperature sensor detects a temperature outside the normal operating range (typically >120°C or an abnormal temperature rise rate) — Atto 3
DTC B2AB6-4B indicates the Electric A/C Compressor internal temperature sensor detects a temperature outside the normal operating range (typically >120°C or an abnormal temperature rise rate).
This fault indicates the compressor internal thermal protection mechanism triggered.
Electrical insulation failure, mechanical friction overheating, abnormal controller drive, or refrigerant circulation faults can cause this condition.
This fault disables the air conditioning cooling function.
In severe cases, thermal management system anomalies may trigger the 'EV Function Limited' protection mode, restricting the vehicle's pure electric driving capability.
It typically does not affect high-voltage system safety.
Compressor insulation failure caused abnormal temperature
Compressor controller fault caused recurring temperature abnormalities
Air conditioning system combined fault (thermostat and controller)
Scroll plate design defect causes abnormal internal temperature