This fault code indicates a short to power or short to ground in the signal circuit of the refrigerant pressure sensor at the plate heat exchanger (Chiller) outlet in the Battery Thermal Management System (BTMS) — Atto 8
This fault code indicates a short to power or short to ground in the signal circuit of the refrigerant pressure sensor at the plate heat exchanger (Chiller) outlet in the Battery Thermal Management System (BTMS).
The plate heat exchanger is a key heat exchange component in the battery liquid cooling circuit.
Its outlet pressure serves as a critical parameter for the system to evaluate refrigerant status and control electronic expansion valve opening and compressor speed.
When a short circuit occurs in the sensor signal wire, the control unit (typically the battery manager or integrated thermal management controller) detects an abnormal voltage signal (near 0V or supply voltage), preventing accurate refrigerant pressure data acquisition.
The system enters fail-safe protection mode and may limit battery charge and discharge power, disable the battery cooling function, or trigger a Level 1 or Level 2 fault warning.
Long-term operation risks traction battery overheating and may trigger thermal runaway protection in extreme cases.
Qin Pro DM threw code B132212 and battery cooling failed after driving through water.
BYD Qin EV300 reports intermittent pressure sensor short circuit after accident repair
BYD Qin Pro EV continuously reports B132212 after Chiller replacement