B160A1A

DTC B160A1A indicates abnormally high resistance (open circuit or high-resistance condition) in the driver-side front airbag (stage 1) ignition circuit — Atto 8

Safety System

DTC B160A1A indicates abnormally high resistance (open circuit or high-resistance condition) in the driver-side front airbag (stage 1) ignition circuit.

This is a critical Supplemental Restraint System (SRS) safety fault.

Normal airbag igniter resistance is 1.5-3.5Ω.

If the system detects resistance continuously exceeding the threshold (typically >5Ω or open circuit), it identifies an ignition circuit integrity fault.

The SRS control unit then illuminates the instrument cluster airbag warning light and enters fail-safe mode.

This condition may prevent the driver-side airbag from deploying during a collision.

The fault indicates an electrical connection issue in the circuit, not an explosion risk from the airbag itself.

5
Cases Logged
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD Qin Pro DM clock spring internal open circuit

Symptoms: The airbag warning light stayed on suddenly during normal driving. Previously, the steering wheel made abnormal noise at full lock. Diagnosis: A diagnostic tool read DTC B160A1A. Removed and inspected the clock spring, revealing wear at the base. Static resistance measured 3.5Ω by multimeter (abnormal). Resistance intermittently went to infinite (open circuit) when turning the steering wheel. Confirmed the internal ribbon cable was broken. Resolution: Replaced the OEM clock spring assembly, cleared the fault codes, and the system returned to normal. Cost: about 300–600 yuan.
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD Song Pro: Airbag connector loose, poor contact

Symptoms: Airbag warning light stays on after accident repair. DTCs reappear after clearing. Diagnosis: Yellow airbag connector under steering wheel not fully seated. Terminal retraction caused contact resistance 5.8 Ω (excessive). Resolution: Repaired terminal using extraction tool. Reconnected and confirmed locking click. Secured wiring loom with cable ties to prevent loosening. Cleared DTCs; fault resolved.
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD e5 commercial vehicle: clock spring ribbon cable fatigue wear

Symptoms: 180,000 km rideshare vehicle. Airbag warning light flashes intermittently then stays on, worse in damp weather. Diagnosis: Prolonged full-lock steering caused the clock spring to exceed its fatigue life. Resistance unstable (fluctuating 1.2–6.8 Ω), jumping when the housing was tapped. Fix: Replaced with a compatible clock spring, greased rotating parts, advised avoiding prolonged full-lock steering. Fault resolved.
BYD DTC AI AnalysisFrom Chinese market (translated)

BYD Tang DM airbag module internal fault

Symptoms: Airbag warning light on with no accident history. Fault returned one month after clock spring replacement. Diagnosis: Confirmed the replacement clock spring was normal (0.8Ω). Disconnected the connector and installed a 2.5Ω dummy resistor at the circuit end; the fault could be cleared, indicating a module issue. Removed and tested the airbag igniter — measured 8.2Ω resistance, severely out of specification. Resolution: Replaced the driver-side airbag module and checked the SRS control unit version at the same time. Fault fully resolved.
BYD DTC AI AnalysisFrom Chinese market (translated)

Steering wheel modification on a BYD Yuan EV damaged the wiring harness.

Symptoms: After reverting from an aftermarket racing steering wheel to the factory unit, the airbag warning light stayed on with DTC B160A1A. A previous attempt to bypass with a resistor had no effect. Diagnosis: Found the wiring harness between the clock spring and airbag module cut and joined with electrical tape. Temperature changes and vibration loosened the tape, causing copper oxidation and a contact resistance of 4.2Ω. Insulation damage was also present. Resolution: Removed the splice point and repaired using a sealed waterproof connector or a soldered splice with heat-shrink tubing, achieving a stable resistance of 2.0Ω. Recommend avoiding modifications that damage the factory wiring harness.