B16AC

For BYD new energy models (Qin, Tang, Song, Yuan, and Han series), DTC B16AC indicates an air conditioning evaporator temperature sensor circuit fault (Evaporator Temperature Sensor Circuit Range/Performance), not the SRS_ECU fault stated in the original information — Atto 8

Safety System

For BYD new energy models (Qin, Tang, Song, Yuan, and Han series), DTC B16AC indicates an air conditioning evaporator temperature sensor circuit fault (Evaporator Temperature Sensor Circuit Range/Performance), not the SRS_ECU fault stated in the original information.

This NTC thermistor mounts on the air conditioning evaporator surface.

It monitors the evaporator temperature in real time to prevent surface icing from blocking the air ducts.

The controller sets this DTC and triggers the air conditioning system protection strategy (compressor shutdown or restricted cooling) upon detecting an out-of-range sensor signal voltage (close to 5V during an open circuit, close to 0V during a short circuit, or unresponsive to temperature changes), abnormal resistance, or an abnormal sampling frequency.

This fault results in a lack of cooling, intermittent A/C operation, or evaporator icing.

5
Cases Logged
BYD DTC AI Analysis

BYD Song Pro DM evaporator sensor circuit open

Symptoms: With A/C on, the system blows ambient air only. Compressor does not engage – no cooling. Intermittent fault. Diagnosis: Connected a Launch X431 and read the A/C system. Retrieved DTC B16AC: Evaporator Temperature Sensor Circuit Open. Removed the glovebox and measured infinite resistance at the sensor connector (spec: 1.5–2.5 kΩ). Traced the pink signal wire between the sensor and controller; found it broken at the glovebox hinge from repeated bending. Repair: Soldered the broken harness wires and sealed with heat-shrink tubing. Rerouted and secured the wiring harness to prevent chafing. Cleared the DTCs – A/C returned to normal operation. Sensor not replaced.
Original source ↗
BYD DTC AI Analysis

BYD Qin Plus EV sensor connector oxidised, poor contact

Symptoms: Air conditioning cooling intermittent, evaporator surface frequently icing up, airflow gradually decreasing. Stored DTC B16AC. Diagnosis: Data stream showed evaporator temperature -25°C (actual ambient 30°C) — signal abnormal. Inspected connector, found obvious green corrosion and oxidation on male/female terminals. Sensor body resistance measured normal, but contact resistance fluctuated between 0.5Ω and 50Ω when connected. Resolution: Cleaned connector terminals with electronic contact cleaner, applied conductive grease to improve contact, reconnected and wrapped with waterproof tape. Fault resolved, no parts replaced.
Original source ↗
BYD DTC AI Analysis

Damaged thermistor in BYD Tang DM sensor body

Symptoms: The A/C stopped working after 5–10 minutes of operation. It recovered after restarting but shut down again shortly after. The temperature display on the A/C panel showed '--' or a fixed 85°C. Diagnosis: Scan tool retrieved active fault B16AC and communication loss code U0164. Sensor supply voltage measured 5V and ground was normal, but signal wire voltage stuck at 4.9V and did not vary with temperature. Fitted a new sensor for comparison – signal voltage returned to normal, varying from 1.2V to 3.8V with temperature changes. Repair: Replaced the A/C evaporator temperature sensor (part no. EG-8103010). Removed the passenger-side dashboard and evaporator housing to access it. Recharged refrigerant and test drove – fault did not return.
Original source ↗
BYD DTC AI Analysis

BYD e5 taxi wiring harness chafed causing short to ground

Symptom: Air conditioning suddenly cuts out when driving on rough roads but works normally on smooth surfaces. B16AC is an intermittent fault code; freeze frame data shows the vehicle was on uneven terrain when the fault occurred. Diagnosis: Inspected the wiring harness routing and found it chafing against the body sheet metal where it passes through the firewall. Stripped back the corrugated conduit to reveal the signal wire insulation worn through, exposing the copper strands. The wire intermittently shorts to ground when the vehicle bounces. The sensor itself tested normal; the controller logged B16AC (signal voltage below threshold) when the short occurred. Repair: Repaired the wiring harness with electrical tape and heat-shrink tubing. Re-routed the harness and fitted a rubber grommet at the firewall opening. Installed a foam sleeve at the rubbing point to prevent further chafing.
Original source ↗
BYD DTC AI Analysis

BYD Han EV control module software false-positive fault detection

Symptoms: Air conditioning stopped cooling at 5,000 km on a new vehicle. Scanned DTC B16AC. Measured the sensor and wiring circuits—both completely normal. The fault occurred more frequently after the vehicle had been parked in the sun. Diagnosis: Measured sensor resistance and voltage—both within specification (approximately 1.8 kΩ at 25°C, signal voltage 2.3 V). Compared the data stream against a known-good identical vehicle; identified abnormal sensor sampling frequency on the faulty vehicle. Consulted the BYD technical service bulletin; confirmed certain batches of AC controller software are sensitive to temperature fluctuations, causing false B16AC codes. Solution: Updated the AC controller software to the latest version (V2.3 or higher). After flashing, monitored the data stream—temperature sampling smoothness improved. The DTC has not returned. Did not replace any hardware.
Original source ↗
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.