DTC B170D indicates the SRS (Supplemental Restraint System) control unit detects an open circuit or disconnection in the right-hand (RH) curtain airbag circuit — Atto 8
DTC B170D indicates the SRS (Supplemental Restraint System) control unit detects an open circuit or disconnection in the right-hand (RH) curtain airbag circuit.
Specifically, during the self-test, the control unit fails to detect the load signal from the RH curtain airbag inflator within the specified time (typically under 6 seconds).
Normal resistance is 1.6-2.4Ω.
This fault prevents the RH curtain airbag from deploying during a side impact or rollover accident, severely compromising occupant head protection, and continuously illuminates the instrument panel SRS warning light.
Determine whether the cause is a loose harness connector, an open circuit in the wiring, or a faulty curtain airbag module.
Song MAX right side curtain airbag intermittently sets fault code after accident repair
Tang DM right side curtain airbag circuit corroded open after wading
Yuan EV side curtain airbag false alarm after window tinting