This DTC indicates the Thermal Management Control Unit (TMS) or air conditioning control module detects a short circuit in the signal circuit of the high-pressure side pressure sensor for the plate heat exchanger (Chiller/battery cooler) refrigerant circuit — Atto 8
This DTC indicates the Thermal Management Control Unit (TMS) or air conditioning control module detects a short circuit in the signal circuit of the high-pressure side pressure sensor for the plate heat exchanger (Chiller/battery cooler) refrigerant circuit.
The sensor outputs an abnormal voltage (near 0 V when shorted to ground, or near 5 V or 12 V when shorted to power), exceeding the normal 0.5–4.5 V signal range.
This piezoresistive sensor monitors real-time refrigerant circuit pressure (typically 0–3.5 MPa) to control the Electronic Expansion Valve (EXV) opening and regulate compressor speed.
The short circuit eliminates system pressure feedback and prevents accurate refrigerant flow control.
This fault can trigger thermal management derating: limiting battery fast-charging power, prohibiting high-power discharge, and reducing motor power output.
In extreme cases, the loss of overpressure protection can cause pipe rupture or compressor damage.
Qin EV plate heat exchanger pressure sensor shorted after water ingress
Wiring harness wear caused intermittent short circuit
Internal short circuit in the sensor
Improper wiring harness routing after repair caused short circuit