DTC B2AB997 indicates the electric air-conditioning compressor (E-Compressor) operating load exceeds the system-calibrated safety threshold — Atto 8
DTC B2AB997 indicates the electric air-conditioning compressor (E-Compressor) operating load exceeds the system-calibrated safety threshold.
The compressor controller or vehicle control unit (VCU) triggers this fault in the BYD Qin EV thermal management system when it detects a compressor drive current continuously exceeding the rated value (typically >15-20A, depending on operating conditions), an abnormal drop in speed feedback (stall risk), or an abnormal rise in torque demand.
The system then registers an 'excessive load'.
This protective fault prevents compressor mechanical damage, high-voltage circuit overload, or thermal management system failure.
The fault can reduce air-conditioning cooling capacity and automatically shut down the compressor.
Extreme cases may trigger high-voltage interlock protection, affecting battery thermal management functions.
Qin EV 2019: Worn compressor scroll plate causing excessive load
Severely clogged condenser caused excessive high-side pressure
Poor contact in high-voltage wiring harness caused abnormal load.
Refrigerant overcharge causing liquid slugging risk
Compressor controller IPM module fault