B2AB049

DTC B2AB049 indicates a malfunction in the current sampling circuit of the electric compressor drive controller in the thermal management system — Seal U

Thermal Management System

DTC B2AB049 indicates a malfunction in the current sampling circuit of the electric compressor drive controller in the thermal management system.

This circuit typically uses a Hall effect sensor or a precision shunt resistor to monitor the compressor motor operating current in real time, enabling overcurrent protection, closed-loop torque control, and stall detection.

The controller sets this fault when it detects a sampled value outside the valid range (e.g., signal line open circuit, short to ground or power, sampled value continuously at zero or saturated, or an abnormal three-phase current vector sum).

When this fault occurs, the compressor initiates a protective shutdown, disabling the air conditioning cooling and heating functions.

If the vehicle uses a heat pump system or relies on the air conditioning system for battery cooling, prolonged operation may overheat the battery or motor, but generally does not directly affect driving safety.

4
Cases Logged
BYD DTC AI Analysis

Current sampling fault restricts EV mode on Qin 80

A BYD Qin 80 hybrid displayed "Check Power System" on the instrument cluster and would not drive in EV mode. Scanning revealed DTC B2AB049 (current sampling fault). Inspection found the current sampling harness connector between the Battery Information Collector (BIC) inside the high-voltage battery pack and the Battery Management System (BMS) had come loose, interrupting the Hall current sensor signal. The technician reseated the connector and applied conductive grease to secure it. After clearing the code, EV mode returned to normal. This case shows that B2AB049 can also indicate BMS-related faults in certain models.
Original source ↗
BYD DTC AI Analysis

Qin EV compressor controller sampling circuit burned out

A 2019 Qin EV with 80,000 km suddenly lost air conditioning while driving; restart did not help. The diagnostic tool showed current sampling fault B2AB049. Disassembling the electric compressor revealed burn damage to the current sensor power supply circuit inside the controller, with scorch marks on the PCB. Compressor three-phase winding resistance measured approximately 1.2Ω and balanced, with good insulation. Diagnosed as internal short circuit in the controller. Replaced the electric compressor assembly and recharged the refrigerant. Fault cleared.
BYD DTC AI Analysis

Intermittent current sampling fault on rough roads

Air conditioning occasionally cuts out when driving over speed bumps but functions normally on flat roads. Read historical DTC B2AB049. Found an intermittent connection at pin 5 (current sampling signal terminal) of the compressor controller low-voltage harness connector. Gently wiggling the harness by hand reproduced the fault. Replaced the compressor low-voltage harness connector and re-secured the harness routing to prevent interference with the body. Fault has not recurred.
BYD DTC AI Analysis

Aftermarket inverter causing current sampling interference

Owner reported that after installing an aftermarket inverter, the A/C system intermittently threw code B2AB049; the fault returned several days after clearing. Inspection found the inverter negative ground shared a chassis ground point with the compressor controller. High-power inverter operation created ground bounce noise that interfered with the current sampling signal. Ran a dedicated ground wire from the inverter directly to the battery negative terminal and added a ferrite core filter to the compressor signal line. Fault eliminated permanently.
Data confidence: Community This information is for reference only. Always consult a qualified technician for diagnosis and repair. Do not attempt high-voltage system repairs yourself.