DTC B173B indicates an abnormal electric A/C compressor speed feedback signal or a communication fault between the compressor controller and the motor — Atto 3
DTC B173B indicates an abnormal electric A/C compressor speed feedback signal or a communication fault between the compressor controller and the motor.
In BYD new energy models (e.g., Tang, Song, Qin, and Yuan series), this DTC belongs to the HVAC subsystem within the Body Control system and specifically involves the electric compressor closed-loop control circuit.
The ECU sets this DTC when the compressor controller (IPM) fails to receive a valid pulse signal from the Hall speed sensor for more than 3 continuous seconds, or when the deviation between the detected actual speed and the target commanded speed exceeds the calibrated threshold (typically >500 rpm).
This fault forces the A/C system into fail-safe mode and stops compressor operation.
Symptoms include a complete lack of cooling, intermittent cooling, or a sharp decrease in cooling performance.
The instrument cluster A/C warning lamp may also illuminate.
Prolonged operation with this fault can degrade high-voltage system insulation or cause controller overcurrent damage.
- 1A faulty internal drive circuit or speed detection circuit in the compressor controller (IPM module) prevents interpretation of the speed sensor Hall signal.
- 2Compressor built-in Hall speed sensor internal fault (damaged sensor chip, demagnetized magnet, increased installation gap due to vibration)
- 3Open circuit, short to ground, or poor connector contact in the speed feedback wiring harness between the controller and compressor (pin corrosion, backed-out pin, or failed waterproof seal)
- 4Unbalanced compressor motor three-phase windings (resistance deviation >10%) or local inter-turn short circuit causes excessive deviation between actual and target speeds.
- 5Outdated air conditioning control module (AC ECU) software. A control strategy bug falsely reports abnormal speed under specific operating conditions.
- 1Connect the BYD dedicated diagnostic tool (VDS2000 or X431). Access the air conditioning system to read the complete DTC and freeze frame data. Confirm B173B is a current fault (Active) and not a history fault (History). Record the compressor speed, current, and voltage data at the time of the fault.
- 2Visually inspect the electric compressor exterior and high- and low-pressure pipe connections. Confirm no refrigerant leaks or physical damage. Check the controller heat sink for overheating and discoloration.
- 3Disconnect the compressor low-voltage connector (usually a 12-pin or 8-pin connector). Use a multimeter to measure the controller-side supply voltage (12V±0.5V), ground resistance (<0.1Ω), and CAN line voltage (CAN-H 2.5-3.5V, CAN-L 1.5-2.5V) to rule out basic wiring faults.
- 4Measure the compressor three-phase motor winding resistance (U-V, V-W, W-U). Normal resistance is 1.0-3.0 Ω (refer to the vehicle repair manual for specific values) and the three phases must balance (deviation <10%). If the resistance is abnormal, replace the compressor assembly.
- 5Use an oscilloscope to check the speed feedback signal wires (typically two thin wires, green/white or yellow/black). A normal signal displays a 0-5V square-wave pulse. Frequency varies with speed (30-90Hz corresponds to 900-2700 rpm). If the signal is missing or distorted, check the sensor and wiring.
- 6Check the tightness of the compressor controller-to-body ground point (usually located on the inner fender or frame rail). Clean the oxidation layer from the ground point using sandpaper, apply conductive grease, and tighten to the specified torque (usually 8-10 N·m).
- 7If all circuit measurements are normal, update the air conditioning control module software (check BYD TPI technical bulletins for relevant update procedures) to rule out a false software fault.
- 8Replace the faulty component: Replace the compressor controller first (some models allow separate replacement; others require replacing the complete compressor assembly). After replacement, perform the air conditioning system initialization matching (self-learning procedure) so the controller recognizes the compressor parameters.
- 9Use dedicated equipment to evacuate the system (vacuum level <-0.1MPa, hold for 30 minutes). Charge the specified amount of R134a refrigerant (usually 600-800g) and POE refrigerant oil (usually 150-200ml, deduct residual old oil). Perform a pressure hold test to verify no leaks.
- 10Clear the fault code. Start the vehicle and set the air conditioning to maximum cooling mode. Observe the compressor speed feedback data stream (actual speed should smoothly follow target speed changes). Verify high and low pressures are normal (low pressure 0.15-0.25MPa, high pressure 1.2-1.6MPa) and confirm the fault is resolved.
Scroll plate seal failure in BYD Tang DM electric compressor caused abnormal speed
BYD EV compressor controller speed detection circuit damaged
Poor contact in BYD Qin Pro DM compressor speed sensor wiring harness